This chiller does NOT have an internal pump for system circulation.
An appropriately sized external pump is required.
CHOOSING THE CORRECT EXTERNAL PUMP
Required pump size depends on chiller model, water volume and rate of circulation. Recommended
pump sizes for effective water chilling are within the following ranges:
Chiller
Model
1/10 HP
1/4 HP
1/2 HP
TYPICAL INSTALLATION
For the most effective water cooling and energy efficiency, locate chiller below water level. If chiller
must be placed above reservoir level, make sure height above pump does not exceed 26 ft. (8m).
For best performance, keep hoses as short as possible. The sum of all hose lengths should not
exceed 25 ft. (7.6m).
Chilled water return
Reservoir
(separate from nutrient pump)
IMPORTANT! Always check the following before starting chiller:
Water level inside the reservoir is correct and there are no leaks in any hoses or connections.
Power supply is correct and the plug is inserted completely into the outlet.
Double-check the whole system to make sure there are no breaks or clogs.
Installation
Max. Reservoir Volume
Gallons (Liters)
42 (160)
80 (300)
132 (500)
Chiller Pump
Rate of Circulation – Pump Size
Gallons Per Hour (Liters Per Hour)
66 - 317 GPH (250 - 1200 LPH)
264 - 660 GPH (1000 - 2500 LPH)
317 - 793 GPH (1200 - 3000 LPH)
WATER
LEVEL
Chiller
5
Hose
Adapter
FITTING
CONNECTION
Seal
Nut
Chiller