ACOPOWER 3x40W Podręcznik - Strona 12

Przeglądaj online lub pobierz pdf Podręcznik dla Panel słoneczny ACOPOWER 3x40W. ACOPOWER 3x40W 15 stron. 3×40w foldable solar panel

Fault Indications:

Status
Icon
Battery over
discharged
Battery over
voltage
Battery
Overheating
Load failure
When load current reaches1.02-1.05 times 1.05-1.25 times, 1.25-1.35 times and
1.35-1.5 times more than nominal value, controller will automatically turn off loads in 50s,
30s,10s and 2s respectively
Load mode setting
Operating Steps:
Under load mode setting interface, press SET button and hold on 5s till the number begin
flashing, then press MENU button to set the parameter, press SET button to confirm.
Timer 1
Light ON/OFF
Load will be on for 1 hour
since sunset
Load will be on for 2 hours
since sunset
Load will be on for 3~13
hours since sunset
Load will be on for 14 hours
since sunset
Load will be on for 15 hours
since sunset
Test mode
Manual mode(Default load
ON)
NOTE: Please set Light ON/OFF, Test mode and Manual mode via Timer1. Timer2
will be disabled and display "2 n".
Description
Battery level shows empty, battery frame blink,
fault icon blink
Battery level shows full, battery frame blink, fault
icon blink
Battery level shows current value, battery frame
blink, fault icon blink
Load overload
,Load short circuit
Timer 2
Disabled
Load will be on for 1 hour
before sunrise
Load will be on for 2 hours
before sunrise
Load will be on for 3~13
hours before sunrise
Load will be on for 14
hours before sunrise
Load will be on for 15
hours before sunrise
Disabled
Disabled
3×40W
Battery Type
Operating Steps
Under Battery Voltage interface, press SET button and hold on 5s then enter into the
interface of Battery type setting. After choosing the battery type by pressing MENU button,
waiting for 5s or pressing SET button again to modify successfully.
Battery Type
①Sealed (Default)
NOTE: Please refer to the battery voltage parameters table for the different battery
type.
Faults
Possible reasons
The
LCD
is
off
during daytime when
PV
sunshine falls on PV
disconnection
modules properly
1) Battery voltage is
lower than 9V
Wire connection is
2) PV voltage is less
correct,
LCD
not
than battery voltage
display
Interface
Battery over voltage
blink
Interface
Battery
blink
over discharged
Interface
Battery Overheating
blink
Interface
Over load or Short
blink
circuit
②Gel
③Flooded

Troubleshooting

array
Confirm that PV wire connections
are correct and tight
1) Please check the voltage of
battery. At least 9V voltage to
activate the controller
2) Check the PV input voltage
which should be higher than
battery's
Check if the battery voltage is
higher than OVD point (over
voltage disconnect voltage), and
disconnect the PV.
When the
battery
voltage
restored to or above LVR point
(low voltage reconnect voltage),
the load will recover
The controller will automatically
turn the system off. But while the
temperature decline to be below
50 ºC, the controller will resume.
Please reduce the number of
electric
equipments
or
carefully loads connection.
is
check