ACOPOWER HY-PTK-100WP20A Podręcznik użytkownika - Strona 11

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Panel słoneczny ACOPOWER HY-PTK-100WP20A. ACOPOWER HY-PTK-100WP20A 14 stron.

ACOPOWER HY-PTK-100WP20A Podręcznik użytkownika
4. Technical Specifications
Item
Nominal system voltage
Max. PV input voltage
Rated current
Equalize Voltage
Boost Voltage
Float Voltage
Low Voltage Reconnect
Voltage
Low Voltage Disconnect
Voltage
Self-consumption
Temperature
compensation coefficient
Working temperature
Enclosure
Overall dimension
Mounting dimension
Mounting hole size
Power cable
Net weight
www.ACOPower.com
LS1012EPD
LS1024EPD
12VDC
12/24VDC Auto
30V
50V
10A
10A
14.8V(12V);29.6V(24V)
14.4V(12V);28.8V(24V)
13.7V(12V);27.4V(24V)
12.6V(12V);25.2V(24V)
11.2V(12V);22.4V(24V)
12V:≤4.58mA;24V:≤6.01mA
-5mV/℃/2V(25℃)
108.5mm×75mm×25.6mm
PV/BAT/LOAD:4.0mm
408g
HY-PTK-100WP20A
LS2024EPD
12/24VDC Auto
50V
20A
-35℃~+55℃
IP67
100.5mm
Φ5
2
PV/BAT/LOAD:6.0mm
410g
435g
4120 Valley Blvd Walnut, CA 91789, USA
+1-626-737 1140
2