LOCATION
Refer to the assembly instructions for
the installation.
To ensure best performance, install the appliance
well away from sources of heat such as radiators,
boilers, direct sunlight etc. Make sure that air can
circulate freely around the back of the cabinet.
POSITIONING
Install the appliance in a dry, well ventilated indoors
where the ambient temperature corresponds to the
climate class indicated on the rating plate of the
appliance.
Climate
Ambient temperature
class
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Some functional problems might occur
for some types of models when
operating outside of that range. The
correct operation can only be
guaranteed within the specified
temperature range. If you have any
doubts regarding where to install the
appliance, please turn to the vendor,
to our customer service or to the
nearest Authorised Service Centre.

TECHNICAL DATA

TECHNICAL DATA
Dimensions of the recess
Height
Width
Depth
Rising time
Voltage
20
ELECTRICAL CONNECTION
Before plugging in, ensure that the voltage and
frequency shown on the rating plate correspond
to your domestic power supply.
The appliance must be earthed. The power
supply cable plug is provided with a contact for
this purpose. If the domestic power supply
socket is not earthed, connect the appliance to
a separate earth in compliance with current
regulations, consulting a qualified electrician.
The manufacturer declines all responsibility if
the above safety precautions are not observed.
This appliance complies with the E.E.C.
Directives.
VENTILATION REQUIREMENTS
The airflow behind the appliance must be sufficient.
5 cm
min. 200cm
min.
200cm
mm
mm
mm
Hours
Volts
2
2
1225
560
550
20
230-240