Something Not Working?

If the appliance is not working correctly, please carry out the following checks before contacting your local
Service Centre.
SYMPTOM
There is no spark when lighting the gas
The gas ring burns unevenly
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.

Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS

Width:
580 mm
Depth:
510 mm
Height:
88 mm
Weight:
12,5 Kg
CUT OUT DIMENSIONS
Width:
550 mm
Depth:
470 mm
Thickness: 30 mm
Burner
Auxiliary (dia. 42 mm.)
Semi-rapid (dia. 57 mm.)
Rapid (dia. 90 mm.)
(*) 1 mbar = 10 mm. water coloumn.
Nominal Power LPG (Butane "A")
kW
kCal/h
Nozzle
0,95
814
50
1,60
1368
65
2,45
2095
80
SOLUTION
Check that the unit is plugged in and the
electrical supply is switched on
Check that the RCCB has not tripped (if
fitted)
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Check the main jet is not blocked and the
burner crown is clear of food particles.
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Supply Connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand
corner
Electric:
230-V 50Hz supply, 3 core flexible cable with
non rewireable plug.
Appliance Gas supply: LPG 30 mbar
Appliance Class: 3
Appliance category: I 3
Diameter
Tap. By-Pass Pressure
gh
75
28
126
35
193
45
Feeding
mbar (*)
30
7