necessary to change the fuse, use a 3 amp AS-
TA-approved (BS 1362) fuse.
A
E
A) Green and Yellow
B) 3 amp fuse
C) Brown
D) Cord clamp
E) Blue
The wires in the cord are coloured as follows:
Green and yellow
Blue
Brown
Replacement of the connection cable
1. Secure the cable by means of the clamp
screws and refit the terminal block cover.
2. Connect the green and yellow (earth) wire
to the terminal in the plug which is marked
with the letter 'E', or the earth symbol
or coloured green and yellow.
3. Connect the blue (neutral) wire to the ter-
minal in the plug which is marked with the
letter 'N' or coloured blue.
4. Connect the brown (live) wire to the termi-
nal in the plug which is marked with the let-
ter 'L'. It must always be connected to the
network phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly at-
tached to the outer sheath.
www.zanussi.com
B
C
D
- Earth
- Neutral
- Live
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to the
voltage and the working temperature. The yel-
low/green earth wire (B) must be approximately
2 cm longer than the brown (or black) phase
wire (A).
Warning! A cut off plug inserted into a 13
amp socket is a serious safety (shock)
hazard. Ensure that the cut off plug is disposed
of safely.
Important! The replacement of electric cable
must be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the current
regulations.
Assembly
min. 600 mm
min. 100 mm
min. 55 mm
30 mm
,
A
B
min. 650 mm
550 mm
11