Installation Instructions
Safety instructions
The laws, ordinances, directives and standards in force in the country of use
are to be followed (safety regulations, proper recycling in accordance with
the regulations, etc.)
Installation may only be carried out by a qualified electrician.
The minimum distances to other appliances and units are to be observed.
Anti-shock protection must be provided by the installation, for example
drawers may only be installed with a protective floor directly underneath the
appliance.
The cut surfaces of the worktop are to be protected against moisture using
a suitable sealant.
The sealant seals the appliance to the work top with no gap.
Do not use silicon sealant between the appliance and the work top.
Avoid installing the appliance next to doors and under windows. Otherwise
hot cookware may be knocked off the rings when doors and windows are
opened.
WARNING!
Risk of injury from electrical current.
• The electrical mains terminal is live.
• Make electrical mains terminal free of voltage.
• Observe connection schematic.
• Observe electrical safety rules.
• Ensure anti-shock protection through correct installation by a qualified
electrician.
• The appliance must be connected to the electrical supply by a qualified
electrician.
IMPORTANT!
Risk of injury from electrical current.
Loose and inappropriate plug and socket connections can make the termi-
nal overheat.
• Have the clamping joints correctly installed by a qualified electrician.
• Use strain relief clamp on cable.
• In the event of single-phase or two-phase connection, the appropriate
mains cable of type H05BB-F Tmax 90°C(or higher) must be used.
• If this appliance's mains cable is damaged, it must be replaced by a spe-
cial cable (type H05BB-F Tmax 90°C; or higher). The latter is available
from the Customer Care Department.
A device must be provided in the electrical installation which allows the ap-
pliance to be disconnected from the mains at all poles with a contact open-
ing width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses (screw type
fuses are to be removed from the holder), earth leakage trips and contac-
tors.
13