Aleko AR2000 Podręcznik użytkownika - Strona 11

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Otwieracz do bram Aleko AR2000. Aleko AR2000 16 stron.

Aleko AR2000 Podręcznik użytkownika
AR2000 SLIDING GATE OPERATOR
Adding extra remote controls (Learn): Press the button 'AN' (See Fig.9 terminal 17) on the
control board, then the 'LED2' will be on and turn off, the beeper will ring about 1 second,
then press the remote control button which you want to use, the 'LED2' will turn on and
then turn off again, the beeper will ring about 2 seconds. The learning process is finished.
Up to 100 remote controls may be used.
Erase remote controls: To erase all existing remote controls, press and hold 'AN' button,
the beeper will ring, release the button once the beeper stops ringing. This indicates that
all the remote controls have been erased completely.
NOTE: For safety and security, we recommend that the factory setting be replaced with a
personal code.
Press the 'OPEN' button of external button switch or remote control button which has been
programmed, the gate will open, the motor rotates clockwise, the output voltage between
'D' and 'D' is AC110V, the voltage between 'U' and 'V' is AC110V. Press 'STOP' button or
the same remote control button, the gate stops running. Press 'CLOSE' button or the same
remote control button again, the gate will close, the motor rotates anticlockwise, the output
voltage between 'D' and 'D' is AC110V, the voltage between 'U' and 'W' is AC110V. Press
the 'STOP' button or the same remote control button, the gate stops running.
Verify open direction: If the gate does not move in the desired direction, then you will need
to reverse the motor operating direction, you can do this by exchanging wires 'V' and
'W', 'OP' and 'CL'.
Position
DIP-switch
ON
1
OFF
ON
2
OFF
ON
3
OFF
Button 3
Fig.10 Remote control
Table 2 DIP-switch
(See Fig.9 terminal 18)
Programming / In this position the control board is in
programming condition, NOT USE condition.
Normal / In this position the control board can be normally used.
Auto-close function and auto-close function of pedestrian mode
are available.
Both Auto-close function and auto-close function of pedestrian
mode are shut off.
Limit switch mode is NC.
Limit switch mode is NO.
11
Button 1
Button 2
Button 4
Function