Clarke 7230602 Instrukcja obsługi i konserwacji - Strona 4

Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Pompa wodna Clarke 7230602. Clarke 7230602 13 stron. Submersible water pump

Clarke 7230602 Instrukcja obsługi i konserwacji

ELECTRICAL CONNECTIONS

nnect the mains lead to a suitable 110 Volt (50Hz) electrical supply through
Co
an approved plug or a suitably fused isolator switch, or to a suitable portable
110 volt transformer.
We recommend that this pump is fitted with a Residual Current Device (RCD).
If the pump is to be connected to an outdoor electrical supply, ensure both
the plug and the socket are of a British Standard approved waterproo
WARNING: THIS APPLIANCE MUST BE EARTHED
The wires in the mains lead are coloured according to with the following code:
Green & Yellow
As the colours of the flexible power cable of this appliance may not
correspond with the coloured markings identifying terminals in your plug
proceed as follows:
• Connect GREEN & YELLOW wire to the terminal marked with a letter "E" or
Earth symbol '
• Connect BROWN wire to terminal marked with a letter "L" or coloured RED
• Connect BLUE wire to terminal marked with "N" or coloured BLACK
IMPORTANT: If you are in any doubt regarding electrical installation, you should
consult a qualified electrician.

PUMP PERFORMANCE DATA

-
Earth
Blue
-
Neutral
Brown
-
Live
'or coloured GREEN or GREEN & YELLOW.
4
design.
f