• You can set the position of the float switch using the clip on the side of
the pump. Adjusting the length of the float switch lead will change the
depth of water at which the pump will turn on or off.
2. The pump can be kept running
continuously by positioning the
float in the raised position but it
will need to be stopped manually
by lowering the float or
unplugging the power cable. This
method can be used to
scavenge the last remaining
water to the 10 mm limit.
3. When finished, disconnect the
pump from the power supply.
CAUTION: DO NOT ALLOW THE PUMP TO RUN DRY
• The pump is fitted with a thermal overload switch. If the pump overheats
for any reason, it will automatically switch the pump OFF. Once the
pump has cooled (at least 5-10 minutes) it will automatically restart.
AFTER USE
If the temperature is expected to be lower than 0°C, ensure there is no
residual water in the pump which could freeze and damage the pump.
If the pump has been used with substances that tend to form a deposit, or
with water containing chlorine, rinse it after use with a powerful jet of water in
order to avoid the formation of deposits which would reduce the
performance of the pump.
MAINTENANCE
WARNING: BEFORE CHECKING THE CONDITION OF THE PUMP, ENSURE IT
IS UNPLUGGED FROM THE MAINS SUPPLY. IF THE UNIT IS HARD WIRED,
ENSURE THE CIRCUIT BREAKER IS OPEN.
This pump should require no maintenance other than regular cleaning. If the
pump shows signs of wear or damage contact your CLARKE dealer for advice.
Check the pump regularly to ensure the water inlet is clear of leaves or other
debris. If foreign material has been drawn into the pump inlet, further cleaning
may be required by back-flushing the pump with water pressure from a hose.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]