High Pressure Lubricant Pump
WARNING
Should leakage occur anywhere within the system,
disconnect air to the motor. Personal injury can occur.
With air pressure at zero:
7 Attach a control valve to the outlet hose of the pump.
8 Set the air pressure to 100 psi (6.9 Bar).
9 Operate the control valve into a container.
10 Allow the pump to cycle until the system and grease is once again
free of air.
11 Shut off the control valve.
•
Visually inspect the pump for external leaks.
•
The pump should not cycle.
If the pump does not stall, refer to the Troubleshooting Chart for
details.
12 Check the motor for air leakage.
If the motor leaks, refer to the Air Motor Service Guide for details.
Installation
Part Number
338860
Moisture Separator/Regulator & Gauge Combination
5604-2
Moisture Separator
7604-B
Regulator and Gauge
5904-2
Lubricator *
Table 5 Air Line Components
* Although the air motor is lubricated at the factory, the life of the
motor can be extended with the use of a lubricator.
Description
Declaration of conformity as defined by
Machinery Directive 2006/42/EC
This is to declare that the design of the low pressure fluid lubricant
pump complies with the provisions of directive 2006/42/CG
Applied standards:
•
EN 292-1 Safety of Machinery - Basic Concepts, General
Principles and Design - Part 1: Basic Terminology, Methodology
•
EN 292-2 Safety of Machinery - Basic Concepts, General
Principles and Design - Part 2: Technical Principles and
Specifications - Incorporates amendments 1 (1995) and 2 (1997)
•
EN 809 Pumps and Pump Units for Liquids - Common Safety
Requirements
•
EN 349 Safety of Machinery - Minimum Gaps to Avoid Crushing
of Parts of the Human Body
St. Louis, MO 08/14,
Bob Hoefler, Director Product Development and Product Engineering