Alemite 8549-B1 Instrukcja serwisowa - Strona 4

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Pompa wodna Alemite 8549-B1. Alemite 8549-B1 13 stron.

Alemite 8549-B1 Instrukcja serwisowa
SER 8540-B
Early Model Pumps
The earlier versions of these model pumps did not contain seals in
the tube assembly. The Piston and Lower Rod cycled in "select-fit"
bores. See Figure 3.
Any earlier model pump that has not been repaired since 1983 re-
quires a 393516 conversion kit.

Conversion Kit

NOTE: In addition to the contents within the kit, the existing pump
tube must be replaced. See Table 2 for the appropriate part number.
Install the Kit
To reassemble the pump with the conversion kit, follow the proce-
dures outlined in the section entitled Assembly.
Pump Tube
1 Pump Model
Part No.
8540-B
337392
8549 Series
337392-2
Noise level test
Distance
60 psi (4,1 bar)
3 ft. (0,9 m)
96 dB
Length
21.25"
30.42"
100 psi (6,8bar)
98 dB
Figure 3 Early Model Pump Tubes- Section View
4
High Pressure Lubricant Pump