6. Double Pulse Lock
1. Off: lock output pulses once
2. On: lock output pulses twice
7. Factory Alarm Disarm function
1. With Unlock: Factory Alarm Disarm wire pulses as programmed, at the same time as the unlock
(Blue) wire, and when remote start is actiavted.
2. Before Unlock: Factory Alarm Disarm wire will pulse as programmed before the unlock wire, and
when remote start is activated.
3. Remote start only: Factory Alarm Disarm wire will pulse as programmed during remote start only
8. Factory Alarm Disarm pulses
1. Single: Factory Alarm Disarm wire pulses once per operation
2. Double: Factory Alarm Disarm wire pulses twice per operation
9. Comfort Closure
1. Comfort Closure 1: door lock pulse (or 2nd pulse for double pulses) will remain on for 20 seconds.
2. No comfort Closure: Comfort Closure is defeated when locking
3. Comfort Closure 2: 800mS following the end of the door lock pulse (or 2nd pulse for double pulses);
door lock output will turn on again for 20 seconds.
10. Panic Mode
1. On: Panic output can be activated at any time
2. Off: Panic output is defeated