Clarke HIPPO Jr Instrukcja obsługi i konserwacji - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Pompa wodna Clarke HIPPO Jr. Clarke HIPPO Jr 6 stron.

Clarke HIPPO Jr Instrukcja obsługi i konserwacji

ELECTRICAL CONNECTIONS

Connect mains lead to a standard 230Volt (50Hz) electrical supply through a BS
1363 approved, 13 amp plug or a suitably fused isolator switch. Additionally, we
strongly recommend that it be connected via a Residual Current Device (RCD).
If used for draining swimming pools or ponds, the pump MUST be fitted with a
Residual Current Device (RCD), with a rated residual operating current of no
greater than 30mA.
If the pump is to be connected to an outdoor electrical supply, make sure that
both the plug and the socket are of a BS approved waterproof design.
In the event that the pump is hard wired into the electrical system, it must be
carried out in accordance with IEE regulations.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
Green & Yellow
As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug proceed as follows:
Connect GREEN & YELLOW cord to plug terminal marked with a letter "E" or
Earth symbol "
" or coloured GREEN or GREEN & YELLOW.
Connect BROWN cord to terminal marked with a letter "L" or coloured RED
Connect BLUE cord to terminal marked with a letter "N" or coloured BLACK
FUSE RATING
The fuse in the plug for this appliance must be rated at 13 amps.
If this appliance is fitted with a plug which is moulded onto the electric cable (i.e.
non-rewirable) please note:
1.
The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.
2.
Never use the plug without the fuse cover fitted.
3.
Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).
4.
Replacement fuse covers can be obtained from your local dealer or most
electrical outlets
5.
The fuse in the plug must be replaced with one of the same rating (13 amps)
and this replacement must be ASTA approved to BS1362.
IMPORTANT:If you are in any doubt regarding electrical installation, you should
-
Earth
Blue
-
Neutral
Brown
-
Live
consult a qualified electrician.