Clarke 3110472 Instrukcja obsługi i konserwacji - Strona 12
Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Narzędzia Clarke 3110472. Clarke 3110472 17 stron. 6pc air scraper tool set
TROUBLESHOOTING
SYMPTOM
Tool runs at normal
speed but slows down
under any load.
Tool runs slowly. Air flows
weakly from exhaust.
Tool will not run. Air flows
freely from exhaust.
Loss of power or erratic
performance.
Tool will not shut off.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
PROBLEM
1. Excessive pressure on
tool.
2. Motor parts worn.
3. Worn or sticking
mechanism due to
lack of lubricant.
1. Motor parts jammed
with gum/dirt.
2. Regulator in closed
position.
3. General airflow
blocked by dirt.
1. Motor vanes stuck
due to buildup of
foreign material.
1. Excess demand on
air supply. Wrong size
or type of inlet
connectors.
2. Moisture or other
restriction in airline
3. Compressor supplies
insufficient air.
4. Air hose leaks.
1. Throttle O-rings
damaged or ill-fitting
in seat.
12
SOLUTION
1. Reduce the force
applied to the tool.
2. Return to your CLARKE
dealer for repair.
3. Drip air tool lubricating
oil into air inlet. Allow oil
to soak moving parts
before using.
1. Examine inlet air filter for
cleanliness.
2. Adjust regulator to open
position.
3. Operate tool in short
bursts.
1. Disconnect air supply
and rotate tool assembly
manually.
2. Try operating tool in
short bursts.
3. Drip a few drops of air
tool lubricating oil into air
inlet to soak moving parts
1. Isolate other air tools in
use. Check air hose and
confirm correct fittings.
2. Vent system and ensure
air reservoir and airline
are free of water.
Insert oil into tool and run
briefly. Confirm no water
is expelled.
3. Ensure flow rate is
adequate for the size of
air tool.
4. Tighten and seal fittings.
1. Return to your CLARKE
dealer for repair.