Claro CFCLSU2LWH Instrukcja instalacji - Strona 13
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Wentylator Claro CFCLSU2LWH. Claro CFCLSU2LWH 15 stron.
Trouble
Fans does not start after
pairing process
Fan keeps beeping, but will
not start.
Fan wobbles.
Fan makes clicking sound.
Model Number
CFCLSU2WH
CFCLSU2LWH
CFCLSU2WHABS
CFCLSU2LWHABS
Possible Cause
A) Remote and receiver are
not paired successfully
B) Battery flat in remote
control
C) Loose wire connections or
plugs to fan/receiver
D) No power goes into the
fan
Loose wire connections or
plugs to fan/receiver
A) Screws on down rod are
not tightened
B) Blades are not balanced
A) Coupling cover does
not sit securely on motor
housing
B) Rubber ring on coupling
cover is removed
Rated Voltage
Motor Consumption Rated Light Power
220-240Vac
Max. 45 W DC Motor N/A
220-240Vac
Max. 45 W DC Motor 18 W LED
220-240Vac
Max. 45 W DC Motor N/A
220-240Vac
Max. 45 W DC Motor 18 W LED
Suggested Remedy
A) Re-pair the receiver and
remote
B) Replace the battery in
remote control
C) Check wire connections
and ensure plugs are
positively connected
D) Check RCD/Switch board
and wiring on premises
Check wire connections and
ensure plugs are positively
connected
A) Retighten the screws on
down rod
B) Use the balancing kit to
balance the blades.
A) Adjust coupling cover and
ensure it sits properly on the
motor housing
B) Check couple cover and
ensure there's a rubber ring
on the top of the cover.
12