• Remove cover
7. SUPPLIED ACCESSORIES
Connection hoses to A/C system
10 AT fuse
Spare external filter
Spanner for filter removal
Supply cable with pliers for connection to the battery
8. CONTROLS
8.2 FUSE
The 10 AT Timed fuse can be replaced by unscrewing the fuse holder at the back of
PROCHONE.
8.3 HYDRAULIC CONNECTIONS
Both hydraulic connections on the front board (PRESSURE and RETURN) are equipped with
quick fittings.
The red hose is for pressure, the blue one for return.
8.4 ELECTRICAL CABLES
The only electrical cable of PROCHONE is the supply cable. It is 4 m long and equipped with
two terminals suitable for connection to the battery.
• Black terminal to be connected to negative pole
• Red terminal to be connected to positive pole
9. USE
9.1 Filling the tank
Unscrew tank cap, check level and top up with product if necessary; screw cap back on.
WARNING: all filling and top up operations must be carried out when PROCHONE is
disconnected from the supply line. Do not use near open fire and sources of heat.
10. FAILURES
10.1
Hydraulic system
In order to replace the components, proceed as follows: unscrew self-closing fittings at the
end of the hoses connected to the part you need to replace. Remove part and hose from
PROCHONE; it will be easier to remove hose from the part and replace the part.
11. MAINTENANCE
WARNING: all maintenance operations are to be carried out when PROCHONE is
disconnected from the supply line and the vehicle. Wear protective garments and follow
sanitary and safety regulations in force.