Operating systems
The server supports the following operating systems:
Microsoft:
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2012
Microsoft Windows Server 2008 R2
Red Hat:
Red Hat Enterprise Linux 7
Red Hat Enterprise Linux 6 Server x64 Edition (Update 5)
SUSE:
SUSE Linux Enterprise Server 12
SUSE Linux Enterprise Server 12 with Xen
SUSE Linux Enterprise Server 11 for AMD64/EM64T (SP3)
SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T (SP3)
VMware:
VMware vSphere 6.0 (ESXi)
VMware vSphere 5.5 (ESXi) (Update 2)
VMware vSphere 5.1 (ESXi) (Update 2)
See the ServerProven® website for the latest information about the specific versions and service levels
supported and any other prerequisites:
http://www.lenovo.com/us/en/serverproven/
Physical specifications
The x3550 M5 server has the following dimensions and weight (approximate):
Height: 43 mm (1.7 in)
Width: 429 mm (16.9 in)
Depth: 734 mm (28.9 in)
Weight:
Minimum configuration: 13.8 kg (30.5 lb)
Maximum configuration: 19.3 kg (42.7 lb)
Operating environment
The x3550 M5 server is supported in the following environment:
Air temperature:
Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 to 950 m (3,117 ft); decrease the
maximum system temperature by 1 °C for every 175-m increase in altitude above 950 m.
Server off: 5 °C to 45 °C (41 °F to 113 °F)
Maximum altitude: 3,050 m (10,000 ft), 5 °C to 28 °C (41 °F to 82 °F)
Shipment: -40 °C to +60 °C (-40 °F to 140 °F) at up to 10,700 m (35,105 ft)
Humidity:
Server on: 8% to 85%, maximum dew point 24 °C, maximum rate of change 5 °C/hr
Server off: 8% to 85%, maximum dew point 27 °C
Design to ASHRAE Class A3, ambient of 40 °C (104 °F), with relaxed support:
Supports cloud-like workload with no performance degradation acceptable (Turbo-Off).
Under no circumstance can any combination of worst case workload and configuration result
in system shutdown or design exposure at 40 °C.