Specifications
Operating Specifications
Maximum Hot Water Supply Temperature185°
Minimum Cold Water Supply Temperature33°
Optimum Minimum Inlet to Outlet Temperature Differential
Optimum Thermostatic Control Range
Flow Rate at 45 psi
Minimum Flow Rate
Maximum Inlet Supply Pressure
Minimum Inlet Supply Pressure
*Model 320 can accept temporary excursions above 185°F (85°C) and maintain control without sustaining
internal damage. (ASSE 1017 certification requires exposure to 200°F (93°C) for a period of 30 minutes).
Prolonged operation of the Mixing Valve at such elevated temperatures is not recommended.
** Normal operating conditions are considered as a differential of approximately 122°F (50°C) between
the hot and cold inlet temperatures, and with differentials of 59°F (15°C) - 95°C (35°C) between the
blend setting and either supply. 59°F (15°C) is the optimum published minimum differential required to
achieve full thermal performance.
General Advisory
This Model 320 Valve has been supplied for this application based upon information provided to Armstrong at the
time the order was placed.
This Model 320 Valve is configured for use in a "dead-leg" piping configuration.
This Model 320 Valve has not been configured for use in a central pumped re-circulation system.
This Model 320 Valve is not designed to deliver tepid water to emergency fixtures.
For further information, please call our technical department 1-269-279-3602 between 08:00 a.m. to
05:00 p.m. EST.
185°F (70°C)*
33°F (1°C) - 77°F (25°C)
59°F (15°C)**
86°F (30°C) - 122°F (50°C)
23 gpm (87 lpm)
1 gpm (3.8 lpm)
150 psi (10 bar)
10 psi (0.7 bar)
5