DIS AO 6004 Podręcznik użytkownika - Strona 13

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Akcesoria DIS AO 6004. DIS AO 6004 14 stron. Audio output unit for dcs 6000

Danish Interpretation Systems

Technical specifications

Digital Section
Sound quality ......... 20 bit audio @ 32 kHz sampling frequency
Analogue Section
Output signal type...............ground lifting transformer balanced
Nominal output level: ...........................0 dBm at nominal input
Max. Output level:..........................................................15 dBm
Frequency response .................................................... 50-15kHz
Signal to noise ratio: .................................................. >85 dBA
Total harmonic distortion: .............................................< 0.1%
General
Power requirement...................................................24-48 V DC
Power consumption ............................................. 2W maximum
Power supplied from
...................................CU 6005 / CU 6010 / EX 6010 / PS 6000
Temperature to guarantee specified performance
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight ............................................................................ 0.84 kg
Dimensions (W x H x D).......... 180 (205) x 38 x 120 (120) mm
Dimensions in bracket are including brackets
Accessories supplied .............................................. User manual
Connectors
DCS-LAN network............................................... 2 pieces RJ45
Analogue outputs connectors ........... 4 - XLR3 male connectors
Remote Control commands in/out
By using SW 6000 the user can control the AO 6004 through
the CU 6005/6010.
The CU 6005/6010 can read/control the following settings:
* ................................. Channel number for each output channel
* .............................................. Volume setting for each channel
The settings can only be read/controlled from the SW 6000.
The CU 6005/6010 continuously monitors the status of the AO
6004 to ensure that updated status of the unit is always present
on the CU 6005/6010.
Specifications are subject to change without notice.
Manual 01 18 04442
User Manual
13