Classic MWDUC08AR Instrukcja serwisowa - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Klimatyzator Classic MWDUC08AR. Classic MWDUC08AR 9 stron.
② Temperature switch
Use this switch to setting the temperature for Cooling
mode.
● On-Off switch
Use this switch to turn on or off the
unit, the unit will only running at
cooling mode..
Note: To protect the compressor,
every time when the customer turn
on the unit, we suggest to wait for
three minutes.
1.2 Remote control
Button ❶ to ❽ is the same with the display control.
❾ One Touch Button
Press this button, the unit will running into the Cooling
mode, auto fan speed, and the setting temperature is
80℉/26℃.
And the timer function will be cancelled.
❿ Clean Air Button (Optional)
Press this button to turn on the ionizer.
⓫ Fellow Me Button (Optional)
Press this button to turn on this function, the remote
has a temperature sensor, to instead of the room
temperature sensor, every 3 minutes the remote will
send a temperature to AC, if the unit do not get any
signal from remote for 7 minutes, the unit will turn off
this function.
⓬ Cancel Button
Press this button to stop the time on or off function. If
only set timer off, and the unit has been turn off, press
cancel button, the unit will turn on.
⓭ Clock Button
Press to set the time.
⓮ LED Button
Press to off or light the digit LED display, only can be
used when the unit is on.
⓯ Reset Button
Reset the remote control to the initial settings.
⓰ Lock Button
Lock the remote control, and do not accept any
operation until press the Lock button again.
2 Electronic function
2.1 Terms and definitions
TA: Temperature of indoor ambient (T1)
TE: Temperature of evaporator (T2).
TS: The set temperature.
DAHT: Sensor of heater
2.2 Protection function
The compressor restart protection functions with a
delay of 3 minutes.
Sensor protection at open or short circuit.
2.3 Fan-only mode
The temperature can't be controlled at the mode,
and the room ambient temperature is display on
LED. The temp only display 32 to 99 ℉(0 to 37℃),
lf out of range will display LO or HI
The Ion/ Timer functions are valid at the fan-only
mode.
2.4 Cooling mode
The temp can be set from 62 to 86℉(17 to 30℃)
The compressor will be activated by sensing the
difference between setting temperature and the
actual ambient room temperature.
The compressor operates as below: