6.3 Charge Curve
1.
Charge at constant current to 3.4 V per cell module (Bulk).
2.
Maintain constant voltage 3.4 V per cell module (Absorption).
3.
Terminate when charge current drops below 2A.
14-24-2800
12-36-6700
12-48-6650
6.4 Discharging
• Set the battery to ON
• Set the load to ON
• Recommended low voltage cut off: 24 V | 36 V | 48 V
Bulk
100%
I1
80%
60%
40%
20%
Voltage - U
Do not charge battery higher than 3.4 V per cell module.
Recommended charge current is 0.5C.
Cell Modules
Model
in Series
8S
12S
16S
Do not discharge battery below recommended minimum
Do not discharge battery at rates greater than
recommended operating currents.
Absorption
U1
Current - I
▲ CAUTION!
▲ NOTE!
I1
U1
110 Adc maximum
27.2 V
150 Adc maximum
40.8 V
130 Adc maximum
54.4 V
▲ NOTE!
operating voltages.
▲ NOTE!
3.6
3.4
3.2
I2
3
2.8
Termination
Charge Current
I2 ≤ 2 A