DISCOVER 12-48-6650 Instrukcja obsługi - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Akcesoria do kamer DISCOVER 12-48-6650. DISCOVER 12-48-6650 14 stron. For motive power applications
Również dla DISCOVER 12-48-6650: Instrukcja obsługi (13 strony), Instrukcja instalacji (6 strony)

DISCOVER 12-48-6650 Instrukcja obsługi

6.4 Discharging

• Set the battery to ON
• Set the load to ON
• Recommended low voltage cut off: 24 V | 36 V | 48 V

6.5 Storage

Systems should be stored out of direct sunlight under the following temperature conditions:
Systems should be put into storage at 80% SOC and checked monthly to ensure SOC does not fall below 20%.
At 20% SOC the battery will self discharge in approximately 2 months.
7. Service & Maintenance
7.1 Warranty Registration
To register your product you will need the serial number of the battery. Visit discoverbattery.com for registration details.

7.2 Inspection

Batteries should be carefully inspected on a regular basis in order to detect and correct potential problems before they do harm.
This routine should be started when the batteries are first received.
• Inspect for cracks in the battery casing
• Check battery terminals and connections to make sure they are clean, free of dirt, fluids and corrosion
• All battery cables and their connections should be tight, intact, and NOT broken or frayed
• Replace any damaged batteries
• Replace any damaged cables
• Ensure correct torque is used for the terminal bolts

7.3 Battery Firmware

Consult the Discoverbattery.com website for the latest battery firmware versions. If a battery firmware update is require, ensure
this is done by a qualified and authorized person using the AES Dashboard software tool.

8. Recycling and Disposal

10
▲ NOTE!
Do not discharge battery below recommended minimum
operating voltages.
▲ NOTE!
Do not discharge battery at rates greater than
recommended operating currents.
Minimum Storage Temperature
Maximum Storage Temperature
▲ CAUTION!
Do not store a discharged battery. Recharge battery after
every use. Batteries that have self-discharged to a severely
discharge state are not recoverable.
-20°C / -4°F
45°C / 113°F