Replacement not necessary
Old Y
Old 9F
Old 9
In the past, a small number of the original springs No. 9F have broken. Beginning January 2000, the design of
the down leveling adjustment was modified to take a stronger spring.
The complete new adjustment is interchangeable with the original adjustment 9.
A broken spring 9 would cause the down leveling speed to be slower. No danger to passengers would arise as a
consequence.
Oct 02
BLAIN HYDRAULICS GmbH • Boellinger Hoefe • D-74078 Heilbronn • Tel. +49 7131 28 21-0 • Fax +49 7131 485216 • www.blain.de • [email protected]
Printed in Germany
Down Leveling
Adjustment 9
Replacement
9

Old Type

1971 - 1999
if operation is normal
Identification
2 x
Advantages of new type
• Smoother deceleration
• Higher mechanical closing force
• Longer spring life
• Easier assembly

New Type

from Jan. 2000
Identification
4 x
New Y
New 9F
New 9