2. Do not paint your smoke detector.
3. The battery cannot be replaced; do not try to replace the battery.
Activate and deactivate the device
The device is deactivated by default before leaving the factory. Before the
device can be used normally, the product must be activated.
Activate: Press the test button over 10 seconds until the red LED indicator lights
up. After you release the test button the smoke detector is activated and can
be used.
Deactivate: Press the test button over 10 seconds until the red LED indicator
blinks twice. After you release the test button the smoke detector is
deactivated and cannot be used.
How to link the smoke alarms
Step 1: Press the test/silence button on one of the smoke alarms 4 times. The
smoke detector enters transmitting mode for 60sec and the green LED will
rapidly flash.
Step 2: Press the test/silence button on the other smoke alarms twice. The green
LED will slowly flash, indicating receiving mode.
Step 3: If pairing is successful, the green LED on the receiving alarms will stop
flashing. When there is an error the green light will continue to flash for 60
seconds followed by a red light for 2 seconds.
How to unlink a smoke alarm
Press the test/silence button on the smoke alarm twice and the green LED will
slowly flash for 60 seconds (receiving mode). After this period, it will stop
flasing and the smoke alarm is unlinked.
Test your alarm
Test the unit to ensure proper operation by pressing the cover. The alarm will
sound if the unit is working well. If there is no sound, refer to the "Trouble
shooting" section.
CAUTION:
1. DO NOT test your smoke detector using an open flame. This may
damage the smoke alarm or ignite combustible materials and start a
structural fire.
2. DO NOT stand close to the smoke detector when the alarm is sounding.
Exposure at close range may be harmful to your ears.
3. Monthly test: test this smoke detector once a month.
LED Indicators
1. Normal status: Green LED Flashes once every 60 seconds.
2. Test status: Red LED flashes once every second.
3. Hush/Silence mode: Red LED flashes once every 8 seconds.
4. Low battery status: Red LED flashes once every 60 seconds and 1 beep
every 60 seconds.
5. Fault status: the alarm will beep every 40 seconds.

Silence Mode

When the smoke detector is going off you can push the test button to pause it
for approx. 10 minutes. During this silence mode the red LED will flash once