TherMiser TME operation
To ensure you follow the instructions correctly, please refer to the diagram below to familiarise yourself
with the layout and meaning of each of the on-screen icons.
1. Time and time interval setting
1.1 SETTInG THE TIME (FACToRy DEFAULT (00:00)
Press the time key
to scroll between hour/minute/day
of the week.
In each mode press the
or
(24hr) & day (1-7). Note: Mon = 1, Sun = 7.
The time and day will now be set.
1.2 TIME InTERVAL AnD TEMERATURE AUTo ConTRoL SETTInGS
Press and hold
for 5 seconds; screen displays 'loop'
(programming mode) then:
A. press
screen displays "12345"
B.
(up) Once Screen displays "123456"
C.
(up) twice Screen displays "1234567"
NOTE: In any of the above modes press
interval setting and target temperature; see 1.3.
1.3 SETTInG THE on/oFF TIME AnD TEMPERATURE
Press
again to enter the 1st time period/temperature setting
(Good morning)
factory default is (06:30 and 22°C).
Press
again and the ON time hour starts flashing
(default: 06:30), press
or
Press
again and the ON time minute starts flashing
(default: 06:30), press
or
Press
again and the target temp starts flashing
(default: 22°C), press
or
Press
again to enter into the 2nd time period/temperature
setting (leave for school/work)
to set, or
Press
again to enter into
setting and repeat as above.
Repeat through all of the remaining periods.
*
These are advanced settings and should be adjusted with caution.
to adjust the time
to select the time
to adjust the hour.
to adjust the min.
to set target temp.
repeat the steps above
3rd time period/temperature

2. Advanced settings

2.1 EnTERInG InTo ADVAnCED SETTInGS MEnU*
Press
so that the screen is off
Then press and hold
+
together. The unit enters the
menu at Status 1: "SEN" and in Function 00 (flashing).
To adjust the settings press
or
To move through menu Items 1-7 press the
See the menu below
Menu
Icon
FuncTIon
no
1
SEN
Controls sensor inputs
Upper limit
of external/
2
OSV
ThermaSkirt sensing
temp,
Differential
hysteresis between
3
DIF
off and on again of
external temp.
Room temperature
4
SFH
upper limit
Room temperature
5
SVL
lower limit
Calibrates tem of unit to
6
ADJ
the room, compensating
for external factors.
7
FRE
Frost protection
8
PON
Power on memory
9
FAC
Factory reset
2.2 LoCK SCREEn/MEnU
To prevent tampering and adjustment of the TherMiser unit, unit, press
seconds
appears. To unlock, press
2.3 LoCK SCREEn/MEnU
Manual Override
. Press
or
and
if heat required. Automatically resets to program mode at next time interval.
button.
oPTIonS
00: Built-in temp sensor only
01: External temp sensor only
02: Built in temp and External
Skirting Temp Sensor
Note: If no external sensor fitted,
"ERR" message displays, unit will
not function
5~99°C
1~9°C
5~99°C
5~99°C
-5~+5°
00: Frost protection OFF
01: Frost protection ON. 5°C
00: Auto memory, no power
01: NO power = no memory
Adjust using
until"00"
then press
to restore
factory settings
for 5 seconds
flashes then disappears.
to override current target temp.
FAcToRY
SeTTInG
00
42°C
2°C
35°C
5°C
0°C
00
00
00
for 5
appears