40 - 60% = The dehumidifier switches off when a humidity of approx. 40 - 60% r.h.
has achieved. And switches on again when humidity is higher than 40-60%.
20 - 40% = The dehumidifier switches off when a humidity of approx. 20 - 40% r.h.
has achieved. And switches on again when humidity is higher than 20-40%.
The smooth setting option of the hygrostat makes a very convenient humidity
control possible for you. If very precise values are requested, you should match the
hygrostat with the information on a precise hygrometer.
Please consider:
Humidity values of a minimum of 40 % - 45 % r.h. can be achieved with a
condensation dryer. An adsorption dryer is to be employed if lower values are
required.
For this purpose, ask your technical consultant.
Optimal climate:
For living rooms, environmental conditions of 20° -25° C and 50 - 60 % r.h. are
recommended.
For building drying, the hygrostat becomes turned at continues running (POS. I).
In the case of the drying rooms with wood equipment (e.g. floors) or paintings,
antiques and similar things should not be fallen below a humidity of 55%.
Ask your technical consultant in the case of special applications.
6.5 Condensate removal
The dehumidifiers AD are serially equipped with water collecting bucket
(AD 550 / AD 650 = 12 ltr / AD 580 / AD 680 = 16 ltr) and hose connector 12 x 2
mm.
The water bucket is in the device on a balance. The balance is activated by the
weight of the full bucket and the device is switched off. Switch off the unit at the
on/off-switch and empty the bucket. After the bucket is placed in the device again,
turn on the device at the on-/off-switch.
A connection outlet 12 mm is placed above the bucket. Remove the bucket
provided that you would like to guide the condensate directly into a drain. Attach a
hose 12 mm to the drain and fix this with a hose clamp. Proceed cautiously in order
not to burst the drain from the condensate tub.
Guide the hose with slope of the device into the drain away (at least 5 cm slope per
meters).
If the dryer is placed on a wall bracket or otherwise increased, the drain hose can
be led by the opening in the balance downward.
ATTENTION:
Make sure that the condensate can always be handled safely.