Aerial AD 810 Instrukcja obsługi - Strona 9

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Osuszacz powietrza Aerial AD 810. Aerial AD 810 14 stron.

Aerial AD 810 Instrukcja obsługi
Red button:
The built in condensate pump works automatically during the drying process. It
pumps out the condensate whenever it is necessary.
For technical reason a small rest of water stays in the pump.
If the device should be transported, we recommend to empty the pump completely.
This is to make sure that no water runs out when you tilt the unit.
To empty the condensate pumpe completely, push the red button until no more
water flows through the hose.
Neon red in the operation panel (Pt. 6.3)
If the red neon in the operation panel lights up, the dryer has been switched off
because there is a fault in the condensate pump.
Check the pump!
Attention:
This fault switch off does not function if a hose has been disconnected or damaged.
Check the internal hose connections regularly to make sure that no condensate
water flows next to the unit.

6.6 Automatic defrosting

During air drying, ice may form at the evaporator. The volume of ice depends on the
ambient conditions prevailing in the room to be dried.
The AD 810 is equipped with an automatic hot-gas defrosting. It ensures that,
depending on the extent of ice formation, the appliance will be defrosted
automatically according to the following principle:
Ø A temperature sensor measures the condition existing in a critical area of the
evaporator.
Ø It transmits the signal for defrosting to the DryLogic-electronic. The DryLogic
finds out if defrosting is necessary, and it will start defrost-mode on its own.
Ø During defrosting the compressor works and the fan does not work
When the ice is defrosted, the dehumidifier will start again with dehumidifying.

7. Operating conditions

AD-condensation dryers are suitable for the effort on construction sites, in
residential buildings, in swimming halls, in garages and storerooms. AD-
condensation dryers work problem-free at the temperature range of +3 to +32°C
and in the case of relative humidity from 40% to 95% r.h. .
The use in rooms with higher temperatures leads to disadvantages at the
compressor. The use in rooms with lower temperatures is ineffective and can lead
to icing.
Also the storage of the dehumidifier at inadmissible temperature conditions can lead
to damages / problems while immediate switch-on. Therefore, make possible short
time for adaptation for the device before switch-on.