PREPARATION AND SETUP

4.1 Arranging the Space

Place the Atmosphere within 2 m / 78.7 ft from the Gravity. Please place it with its back at least 10 cm / 3.9 inch from a wall to
allow for the hose and cabling to be installed. Reserve the following minimum dimensions for the most convenient access:
Width: 45 cm / 17.71 inch
Depth: 100 cm / 39.3 inch
Height: 100 cm / 39.3 inch
WARNING: IT IS NECESSARY TO PLACE THE ATMOSPHERE IN A WAY THAT ALLOWS YOU TO BE ABLE TO PULL THE
PLUG FROM THE MACHINE OR POWER OUTLET.
CAUTION: Always allow for the Atmosphere to have access to free flowing air at the bottom and the back to
maintain functionality.

4.2 Connect to Power

Connect the Atmosphere to a wall socket that is working on a separate fuse to the Gravity.

4.3 Connect with the Gravity

To function the Atmosphere must be connected to the Gravity.
1. Connect an Ethernet cable to the Atmosphere's back and the RJ45 socket on the bottom back right corner of the Gravity. The
cable must be locked in position 2.
2. Connect the included hose to the push in fitting on the back of the Atmosphere and the push in fitting on the bottom back
right corner of the Gravity.
IMPORTANT!: The hose must at all times allow for free flow through it. Please pay attention so that the hose is
never compressed or folded.

4.4 Moving the Atmosphere

Please contact 3D Systems Support if you want to move the equipment.