Baltech ACCESS100 Instrukcja obsługi - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Czytnik kart Baltech ACCESS100. Baltech ACCESS100 5 stron.
J5: Screw-Clamp, pluggable, 9-Pole. Alternative, potted devices: pigtail cable 1m length.
Pin# Color
1
Black
2
Red
3
Blue
4
Pink
5
Grey
6
Yellow
7
Green
8
Brown
9
White
RS485 interface termination resistor: 120 Ohms, to be connected between Mult_A and Mult_B at both ends of the
RS485 bus lane cable. Stub line length 1 m max.
J10: Through holes, 4-Pole
Pin# Color
1
2
Magenta
3
Grey-pink
4
Red-blue
J8: Service Interface AMP MicroMatch 6-Pole
Pin# Name
Physical
1
TX
RS232 / CMOS
2
RX
RS232 / CMOS
3
GND
GND
4
+5V
5V 5%
5
NC
RS232 / CMOS
6
NC
RS232 / CMOS
Operation
Whenever the device is connected to a proper power supply, it will switch on the internal antenna
and periodically scan for a card. Once a card has been detected, the card number is read, the data
converted and sent to the host system through the serial interface. To enable the device to read
cards, tags and key-fobs successfully, they should be placed centered above the reader. The reader
may also provide a keypad that may used to enter user identification number.
3
RS485 / Wiegand
Name
GND
+VIN
Mult_A: 485/WIE_D0
Mult_B: 485/WIE_D1
LEDGN
LEDRD
REL_WC
REL_NO
REL_NC
RS232/CMOS
Name
+5V
GND
RX
TX
Description
Reader transmit
Reader receive
5VDC supply reader (if connected, the +VIN from J5 must not be
connected)
Do not Connect!
Do not Connect!
Description
Power and Signal GND
Supply Voltage (9...30 VDC)
RS485 A or Wiegand data 0, depending on configuration
RS485 B or Wiegand data 1, depending on configuration
Wiegand: LED-control input
Wiegand: LED-control input
Relais working contact (not installed for ACC-Versions)
Relais normal open (not installed for ACC-Versions)
Relais normal closed. (Special option, available by ordering
from factory: Wiegand-Interface Buzzer control input
Description
Power
GND
RS232 / CMOS
RS232 / CMOS