Baltech ACCESS200 Instrukcja instalacji - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Czytnik kart Baltech ACCESS200. Baltech ACCESS200 3 stron.

Blue
White/Brown
Brown
2. Set bus address
When using a bus protocol (e.g. OSDP), set a bus address for each reader: Place a BALTECH
AdrCard in front of the reader and wait for the signal indicating the desired address.
Note: If the readers are already configured, make sure the reader housing (i.e. the tamper
switch) is open when setting the bus address.
Learn more here:
docs.baltech.de/bus-address
or scan the QR code.
3. OPTIONAL: Test reader functionality
By default, the readers will now read any card's UID (serial number) and transmit it to the
host system. You can make use of this behavior to check if the readers are up and running:
Use a test card and configure the host system temporarily to accept this card's UID.
4. Deploy configuration
If you have a BEC file, deploy it via USB using our Windows tool BALTECH Uploader. If you
have a BALTECH ConfigCard, present it to the reader and wait for yellow and green signals.
Learn more here:
docs.baltech.de/deploy
or scan the QR code.
BALTECH AG
Phone:
Lilienthalstrass<e 27
Fax:
85399 Hallbergmoos
Mail:
Germany
Website:
10
11
12
+49 (811) 99 88 1-0
+49 (811) 99 88 1-11
www.baltech.de
REL_WC
J8-9
REL_NO
REL_NC
REL_NC
v1.0