5. Technical data
5.1 General
Measured quantity:
Tilt angle
Measuring principle:
Magnetic, one-dimensional
inclination transmitter with hall
sensor and oil-damped pendulum
system, hermetically sealed, con-
tact free, freely rotatable without
stops
X axis
Pendulum damping:
by oil fi lling
5.2 Measuring input
Measuring range:
-180°...179.9°
Inclination angle:
Fixed adjustment -180,0°...+179,9°
Sense of rotation:
Adjustable for rotation clockwise or
counter-clockwise
5.3 Measuring output
Power supply:
9...33 VDC
protection against wrong polarity
Output signal:
14 Bit binary code
Protocol:
SSI
Max. clock rate:
1 MHz
Current consumption:
< 100 mA
5.8 Dimensional drawings
69
[2.717]
27.2
[1.071]
N
oil damped pendulum
C
S
3
3
[0.118]
[0.157]
4
5.4 Accuracy
Basic accuracy:
± 0.2 ° (at +25 °C)
Resolution:
14 bit
Transient response:
by 25° tils < 1 sec.
Infl uence of temperature
output current
(–30°...+70°C):
± 0.1° / 10K (>100°)
[-22 ... +158°F]
5.5 Installation data
Material:
Housing cap: (3.2382)
Aluminium GD-AlSi10Mg coated
Housing fl ange: (3.2315)
Aluminium AlMgSiF30
Mounting position:
Perpendicular to the measurement
object
Electrical connection:
Connector M12x1, 8 poles
Weight:
0.3 kg [9.645 oz]
5.6 Regulations
Spurious radiation:
EN 61 000-6-3
Immunity:
EN 61 000-6-2
Test voltage:
500 Veff, 50 Hz, 1 min.
Housing protection:
IP 66 acc. to EN 60 529
5.7 Environmental condition
Climatic rating:
Temperature -30° to +70° C
[-22 ... +158 °F]
Relative humidity < 95%
Vibration resistance:
≤ 40 m/s
acc. EN 60068-2-6
Shock resistance:
300 m/s
acc. EN 60068-2-27
Transportation and
storage temperature:
-30° to +70° C [-22 ... +158 °F]
66.2
[2.606]
60.1
[2.366]
Ø11
[0.433]
2
/ 5 ... 100 Hz
2
/ 18 ms
Ø6.4
[0.252]
11