esera automation 20020 Podręcznik użytkownika - Strona 3

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Akcesoria esera automation 20020. esera automation 20020 4 stron. With pulse output and heating

esera automation 20020 Podręcznik użytkownika
Art. No. 20020
6
Connection example 1-Wire System and 1-Wire Controller / 1-Wire Gateway
7
Software / Evaluation
The wind sensor delivers 4 pulses per revolution. To calculate the wind speed, the pulses are usually counted for
a period of e.g. 1 minute, in our example by the ESERA 1-Wire S0 counter 11211 and then divided by the factor 4
(4 pulses = 1m/s). The result is the wind speed in m/s.
To get to Km/h, the value m/s is multiplied by 3600 and then divided by 1000.
Formula:
Counter reading new - Counter reading old = Delta
Wind speed: m/s = delta / factor (4), Km/h = m/s x 3600 / 1000
8
Operating conditions
The sensor may only be operated at the specified voltages and ambient conditions. The operating position of the
device is vertical. The sensor is designed for continuous outdoor operation.
Due to the heating inside the sensor, the housing heats up. Do not operate the sensor in an
environment in which flammable gases, vapors or dusts are present or may be present.
9
Disposal instructions
Do not dispose of the device in domestic waste! Electronic devices are to be disposed of
according to the Directive on waste electrical and electronic equipment (WEEE) on local
authorities and collection points for waste electronic equipment!
10
Safety instructions
When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, especially
VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860
All final or wiring work must be carried out with the power turned off.
Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
Components, modules or devices may only be put into service if they are mounted in a contact proof housing.
During installation they must not have power applied.
Tools may only be used on devices, components or assemblies when it is certain that the devices are
disconnected from the power supply and electrical charges stored in the components inside the device have been
discharged.
Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults
or breaks.
If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty
cable has been replaced.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change.  ESERA-Automation, E-Service GmbH 2019
www.esera.de
20020 V1.0 R1.0 Manual
Page 3 of 4