Art. No. 19200
11
Software
Data interface Modbus RTU and ESERA ASCII text protocol
You can address the 1-Wire Gateway either by the USB slave socket on the top of the device or by the
internal data interface between the 1-Wire Gateway and the Embedded Computer.
When the USB slave interface is used, internal communication among 1-wire gateway and Embedded
Computer will automatically be interrupted. Both, USB slave and internal serial interface have the setting
19200 baud, 8 data bits, 1 start bit and no stop bit (19200,8N1).
The software "Config Tool 3" for Windows operating systems can be found in the download area of the
article or at our website, Service & Support, Download.
firmware-1-wire-controller-1-wire-gateway/.
This software is available for download on our webpage.
12
Integration IP-Symcon / ESERA-Station
ESERA IP-Symcon software modules are provided at our webpage for easy integration of the ESERA-Station
1-Wire Gateway. Using software scripts are no longer necessary. Further details can be found on our
webpage:
https://www.esera.de/kompatible-steuerungen-zentralen/ip-symcon-integration/.
A script for regular connections by 1-Wire Bus Coupler is also available for download on our webpage. Further
details can be found in the sample script.
13
Configuration and communication 1-Wire Gateway
The well-tested 1-Wire Gateway is installed inside the ESERA-Station. The 1-Wire Gateway has a wide
range of configuration and formatting options, which are read out and operated with the ESERA "Config-Tool
3". For communication among 1-Wire Gateway and Config-Tool 3 the open ESERA ASCII text protocol is
used. Any communication can also be handled directly from the Embedded Computer or a terminal program
(e.g., Hercules or Putty).
Binary inputs and outputs are available by 1-wire gateway for the Embedded Computer to control.
14
Firmware update 1-Wire Gateway
Firmware will be updated by using an existing USB
connection (USB slave module top side) with
Config-Tool 3 software which can be found at the
"DEBUG/DATA" tab. By clicking the button
"DOWNLOAD FIRMWARE" a new window opens to
download new software (firmware) for the 1-Wire
Controller / 1-Wire Gateway.
This firmware is compatible with all releases of the
1-Wire Controller and 1-Wire Gateways as well as
ESERA-Station 200. The features are individually
unlocked at the installed device.
Recovery function Firmware-update
Should an error occur during the firmware update
e.g. losing power while updating the firmware, a
recovery function can be started. Press and hold
the reset button (module bottom side (inside). Then start the update in Config-Tool 3 and release the reset button
after 1 second after the update has been started. The update should start now.
When the updated is completed we recommend to disconnect ESERA-Station 200 for approx. 30 seconds, then
restart again. If any issues should occur when installing the update, please contact the ESERA support team:
E-Mail: [email protected].
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
https://www.esera.de/produkte/software/downloads-
19200 V2.0 R1.0 Manual