dIXEL
LED
MODE
FUNCTION
- Instrument in stand by.
ON
- In "Pr2" indicates that the parameter is also present in "Pr1".
°C
ON
°C
°C
FLASHING
If measurement unit is °C, it flashing on programming mode
°F
ON
°F
°F
FLASHING
If measurement unit is °F, it flashing on programming mode
ON
The compressor is running
FLASHING
- Anti-short cycle delay enabled
ON
The defrost is enabled
ON
Heating enabled
FLASHING
Temperature Set programming phase
ON
- ALARM signal
ON
Fan is running
ON
RH%
ON
Dehumidifying enabled
ON
Humidifying enabled
FLASHING
Humidity Set programming phase
(umid)
ON
Running phase is in progress
FLASHING
Dripping or stopping phase is in progress
FLASHING
Setting of the duration of the cycle
8.2 HOW TO SEE AND MODIFY THE SET POINT (TEMPERATURE AND HUMIDITY)
1.
Push and immediately release the SET key: the display will show the Set point
valueand the correspondant set icon starts flashing;
Or
To change the Set value push the o or n arrows within 10s.
2.
3.
To memorise the new set point value push the SET key again or wait 10s.
8.3 TO START A MANUAL DEFROST
1.
Push the DEF key for more than 2 seconds and a manual defrost will start.
8.4 TO START A EXTRACTION CYCLE MANUALLY
Hold pushed the UP key for more than 2 sec.
To stop manually the cycle: when the cycle is running, hold pushed the UP key for more
than 2 sec.
8.5 TO ENTER IN PARAMETERS LIST "PR1"
To enter the parameter list "Pr1" (user accessible parameters) operate as follows:
Enter the Programming mode by pressing the SET %RH+ n for few
1.
seconds. (°C or °F start flashing)
+
2.
The instrument will show the first parameter present in "Pr1"
8.6 TO ENTER IN PARAMETERS LIST "PR2"
To access parameters in "Pr2":
1.
Enter the "Pr1" level.
2.
Select "Pr2" parameter and press the " SET %RH " key.
3.
The "PAS" flashing message is displayed, shortly followed by "0 - -" with a flashing zero.
4.
Use o or n to input the security code in the flashing digit; confirm the figure by pressing " SET %RH ".
The security code is "321".
5.
If the security code is correct the access to "Pr2" is enabled by pressing " SET %RH " on the last digit.
1592017410 XLH360 GB r1.0 15.04.2005.doc
Operating Instructions
XLH360
cod. 1592017410
7/16