BMA 360D Commands

2. BEAMREPORT

Generates a single all beam report of current activity status.
Query format: BEAMREPORT
Response format: BEAMREPORT [b12][b11][b10][b9][b8][b7][b6][b5][b4][b3][b2][b1]
[bx] = 1 Active beam, 0 = Inactive beam

3. BREPORT

Initiate or halt continuous reporting of active beams.
Command format: BREPORT [x]
[X] = 0 Report disable, 1 Report averaged active beam, 2 Fast reporting of active beams
Query format: BREPORT
Response format: BEAMREPORT [b12][b11][b10][b9][b8][b7][b6][b5][b4][b3][b2][b1]
[bx] = 1 Active beam, 0 = Inactive beam

4. BFZONE

Enable/disable specific beams.
Command format: BFZONE [beam] [enable]
[beam] = 1 to 12
[enable] 1 = on, 0 = off
Query format: BFZONE [beam]
Response format: BFZONE [beam] [enable]

5. DANTEIP

Reports the IP address of the Dante interface.
Query format: DANTEIP
Response format: DANTEIP [IP address}

6. DANTEMAC

Reports the MAC address of the Dante interface.
Query format: DANTEMAC
Response format: MACADDR [MAC address]