Alarm input, output description:
Step 1
Connect alarm input device to the alarm input of I/O cable.
Step 2
Connect alarm output device to the alarm output of I/O cable, alarm output is collector open
circuit output which connects 10K resistor to 3.3V externally.
Step 3
Open the Web, set alarm input and output correspondingly. Alarm input on WEB corresponds
to I/O cable on device. When there is alarm, alarm input device will generate signal of high
and low level. Set corresponding NO and NC inputs.
Step 4
Set the WEB alarm output. The alarm output is for the alarm output port of the device. It is the
alarm output port of the I/O cable.
Please refer to the following figure for alarm input information. See Figure 1-7.
Alarm input: When the input signal is idle or grounded, the device can collect the different statuses of
the alarm input port. When the input signal is connected to 3.3V or it is idle, the device collects the
logic "1". When the input signal is grounded, the device collects the logic "0".
Please refer to the following figure for alarm output information. See Figure 1-8 and Figure 1-9.
Figure1-6