Artic AR-SC7P-192F-M Instrukcja instalacji - Strona 11
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Konwerter mediów Artic AR-SC7P-192F-M. Artic AR-SC7P-192F-M 16 stron. Horizontal fiber optic splice closure
on the cable, let the cable 5mm above the hose clamp, tighten the nut in order to fix the
cable. After that, release the reinforced core device, through the core and screws. Finally put
the small sealing gasket, gasket ring, nut through the tube, tighten the nut in order to seal
properly.
5.6.2 Install the mini cable in the small port: First according to the mini cable way and put it
into the sealing ring, fixed the mini cable reinforced core, and then together through cable
access port, fixed mini cable components, then tighten the nut in order to seal properly.
5.6.3 The big port for straight splice and part branch: should be based on the actual
installation of the cable diameter, use the appropriate double-hole sealing. Unscrew the two
fastening screws, platen, double hole ring and washer, and then put the tube into the ports,
At last put the gasket, double hole ring, and the plastic platen, and finally tighten two
fastening screws to ensure sealing.
5.6.4 Uncutting cable and the fix the reinforced core: according to the diameter of the cable,
choose the right hose clamp, jammed in the slot of reinforced core base. Then put the hose
clamp on the cable, let the cable 5mm above the hose clamp, tighten the nut in order to fix
the cable. After that, release the reinforced core plate, through the core and screws; fix the
direct through cable in the storage tray.
5.6.5. Demount the nut of fixing device of reinforced core with special wrench (plastic one),
set the reinforced core into fixing slot, tighten the nut, and retighten it with metal wrench
(metal wrench to be provided by operator). See drawing 6.
Important issues: tighten the reinforce core fixing screws.
Reinforced core plate
12
INSTALLATION MANUAL HORIZONTAL FIBER OPTIC SPLICE CLOSURE AR-SC7P-XXXF-M