Artidor AR-024 Podręcznik użytkownika - Strona 2
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Akcesoria Artidor AR-024. Artidor AR-024 8 stron. Explosion-safe occupancy sensor
1.
Safety Instructions
The AR-024 occupancy sensor is an explosion-safe product suitable for use in hazardous areas with explosion hazard
from flammable gases, vapors, mist and dust, classified as Zone 2 or Zone 22.
This manual must be read and understood for safe use of the occupancy sensor. All warnings and instructions must be
followed.
Installation must be carried out by personnel trained and qualified in explosion safety taking the instructions
mentioned on the equipment and in this manual into consideration. Local regulations that apply to the installation
must be followed.
Connect this equipment to the supply voltage for which it is designed.
Isolate electrical power to the occupancy sensor before electrical installation.
The protection degree against ignition "Encapsulation", "Increased safety" and "Protection by enclosure" have
been applied to the apparatus. The enclosure may not be opened if the occupancy sensor is energized.
Installation of cables may not invalidate the "Protection by enclosure", therefore only IP65 cable glands with the a
clamping size meeting the cable diameter should be used.
All unused openings should be plugged off in a properly closed and tight way.
Either decommission the occupancy sensor or do not use it when it is damaged.
During installation of the occupancy sensor national safety regulations must be observed.
Only use the occupancy sensor under the environmental conditions for which it is specified. Deviating
environmental conditions can contribute to damage to the equipment and may lead to possible danger to the life
of the user.
Do not use the occupancy sensor at temperatures deviating from the specified ambient temperature range.
Follow all instructions written on the equipment and as mentioned in this manual.
Repairs may only be carried out by the manufacturer or by a person appointed by the manufacturer.
Modifications to the equipment or changes to the design are not permitted.
The product may only be used for the function for which it is designed and shall be maintained in a good and
clean condition.
If these instructions are not followed, the explosion safety of the equipment cannot be guaranteed. The equipment
could then endanger the life of the user and could cause the ignition of an explosive atmosphere. Consequently, Artidor
as the manufacturer will waive any responsibility.
2.
Description
The explosion-safe occupancy sensor AR-024 is based on passive infrared technology and capable of detecting
movements of heat sources. Thanks to the wide opening angle and its 10 m range, this sensor is suitable for
User manual explosion-safe AR-024 occupancy sensor
Issue April 2020
2 / 8