Cleco Tools CellCore P2402KA Instrukcja szybkiej instalacji - Strona 14
Przeglądaj online lub pobierz pdf Instrukcja szybkiej instalacji dla Kontroler Cleco Tools CellCore P2402KA. Cleco Tools CellCore P2402KA 16 stron. Data transmission

3
Setting up the mPro200GC-AP
EN
3.5
Installing the tool on the controller
Up to 16 tools can be connected to one controller.
1.
Select Navigator > Tool Setup on the user interface of the controller.
2.
Press <Install> to add a tool to the tool list.
3.
Carry out the following settings:
4.
Press <OK> and save the settings.
→ The Tool List is displayed.
→ Status of tool is now Needs User Acceptance.
5.
Select <Tool Settings>.
6.
Check the Model Number and Serial Number and confirm that the tool displayed corresponds to the
tool connected.
7.
Save the settings with <Accept>.
→ The Tool List is displayed. Status of tool is now online.
8.
Select <Navigator>.
→ The settings are saved.
9.
For additional programming for tightening (e.g., PG), see Document P2280PM.
14
Parameter
Group Name
Name
Type
IP address/Hostname
Description
Select Tool Group.
Enter Tool Name.
Select LiveWire/CellCore w/WLAN.
Enter the IP address that has been assigned to the tool using the Live-
Wire Utilities software.
P2402KA | 2019-05
Apex Tool Group