DJO VenaGo Skrócona instrukcja obsługi - Strona 2
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Sprzęt medyczny DJO VenaGo. DJO VenaGo 2 stron.
Również dla DJO VenaGo: Skrócona instrukcja obsługi dla pacjenta (2 strony)
What is DVT?
Deep Vein Thrombosis (DVT) is when blood forms a blockage or a clot inside your veins. DVT usually forms in the lower leg or thigh. A DVT could break
off from the wall of the vein, travel up in the body, and get stuck in the lungs. This type of clot, called a Pulmonary Embolism (PE), can be fatal. With so
many clot-related deaths every year, it is important to learn how to prevent DVT so that every preventative measure possible can be taken.
Why Use VenaGo™?
Thromboembolic risk can extend to 30 plus days post-discharge.
CLEANING & DISINFECTING:
• NOTE: Inspect the unit and clean and disinfect prior to each use.
• WARNING: Unit must be turned off and disconnected to the wall prior
to cleaning and disinfecting.
• DO NOT IMMERSE UNIT IN ANY LIQUID FOR ANY REASON.
• Clean the outer surface of the unit with a soft cloth moistened with
soapy water or 70% isopropyl alcohol. Do not use abrasive or volatile
cleaners.
• Do not place cuffs in dryer.
• NEVER remove the unit from the cuff.
• Hand wash the exterior of the cuff with a soft cloth moistened with
soapy water (or 70% isopropyl alcohol) and let air dry.
• To ensure that the unit is completely dry prior to use, set the unit in
the OFF condition, disconnected from the wall outlet for thirty (30)
minutes after cleaning or disinfecting.
PURPOSE OF THIS DEVICE:
The purpose of the VenaGo™ is to aid in the prevention of Deep Vein
Thrombosis (DVT) by aiding in the stimulation of blood flow in the legs.
This is accomplished by an electronically controlled pump delivering
a set amount of air to the leg cuffs that, in turn, compress the calf
or calves to aid in blood flow out of the extremities. The pump will
inflate each leg cuff to a preset level of 50mmhg and deflate once the
pressure is reached. The cycles are repeated on each unit until the
power is turned off. Internal rechargeable batteries allow the VenaGo™
to be completely portable, thus helping to prevent interruption in
treatment.
INDICATIONS:
The VenaGo™ is intended to be an easy to use portable system
prescribed by a physician for use in the home or clinical setting. It aids
in the prevention of DVT by stimulating blood flow in the extremities
(simulating muscle contractions).
CONTRAINDICATIONS:
The VenaGo™ device must not be used to treat the following conditions:
• Persons with suspected (active or untreated) deep vein thrombosis,
ischemic vascular disease, severe arteriosclerosis, pulmonary edema,
severe congestive heart failure, thromboplebitis, or an active infection.
On the legs where the cuffs would interfere with the following
conditions:
• Vein ligation, gangrene, dermatitis, open wounds, a recent skin graft,
massive edema, or extreme deformity of the leg.
• On any neuropathy.
• On extremities that are insensitive to pain.
• Where increased venous or lymphatic return is undesirable.
T 800.336.6569
F 800.457.4221
1430 Decision Street I Vista, CA 92081-8553 I U.S.A.
djoglobal.com/aircast
Copyright © 2021 by DJO, LLC
MKT00-10648 Rev A
Individual results may vary. Neither DJO, LLC nor any of its subsidiaries dispense medical advice. The contents of
this document do not constitute medical, legal, or any other type of professional advice. Rather, please consult your
healthcare professional for information on the courses of treatment, if any, which may be appropriate for you.
WARNINGS AND PRECAUTIONS:
• Medical Electrical Equipment needs special precautions regarding
EMC. Portable and mobile RF communications may be affected by
other Medical Electrical Devices.
• Cuffs used in combination with warming devices may cause skin
irritation. Check regularly for patient compliance, discomfort, and
skin irritation.
• To aid in the prevention of extremity compartment syndrome, special
attention should be given to patients who are positioned in the supine
lithotomy position for extended lengths of time. This includes patients
with or without cuffs.
• Do not open or remove covers.
• If pulsations or throbbing occur, the cuff may be wrapped too tightly.
Loosen immediately.
• STOP using the device if swelling occurs; consult physician.
• Device is to be used only by the patient prescribed and only for its
intended use.
• Unit should not be used in the presence of any flammable anesthetic
mixture with air, oxygen, or nitrous oxide.
• DO NOT IMMERSE in any liquid for any reason.
• DO NOT OPERATE device in a wet environment.
• Allow cuffs to warm to room temperature if exposed to temperatures
below 5̊C or (41̊ F).
• Do not subject the pump to extreme shocks, such as dropping the
pump.
• Contains no serviceable parts. Contact Product Support 888.405.3251.
• Do not place any items in an autoclave.
• Operation of this device can be done by the patient.
• No service is to be attempted when the device is in use.
• This device is NOT to be altered or modified.
WARRANTY:
For a period of sixty (60) days from the date of sale, DJO, LLC will repair
or replace all or part of the unit and its accessories for material or
workmanship defects
FOR SINGLE PATIENT USE ONLY.
NOT MADE WITH NATURAL RUBBER LATEX.