Hardware Installation 2
Refer to the connection diagrams for connection examples as you do the following:
1. Plug your Local Console's keyboard, monitor, and mouse into the unit's Console Ports. Each
port is color coded and marked with an appropriate icon
Note: 1. You can use any combination of keyboard and mouse connections. For example,
you can use a PS/2 keyboard with a USB mouse.
2. USB keyboards and mice can plug into the USB ports on the front panel, as well as
into the ports in the console port section.
3. The KN2116A / KN2132 / KN4116 / KN4132 does not support distances that
exceed 20m between itself and the local monitor.
2. Use Cat. 5e/6 cable to connect any available KVM port to a KVM Adapter Cable that is
appropriate for the server you are installing.
Note: The distance between the KN2116A / KN2132 / KN4116 / KN4132 and the KVM
Adapter Cable must not exceed 40m.
3. Plug the connectors on the KVM Adapter Cable into the appropriate ports of the server you
are installing.
4. Plug a cable from the LAN or WAN into the KVM Over the NET™ switch primary network
interface socket.
5. (Optional) Plug another cable from the LAN or WAN into the KVM Over the NET™ switch
backup (secondary) network interface socket.
6. (Optional) Use Cat 5e/6 cable to connect the KVM Over the NET™ switch PON port to an
SA0142 Adapter. Connect the Adapter to the PON IN port of a PN0108 Power Over the Net™
unit.
7. (Optional) Use Cat 5e/6 cable to connect the KVM Over the NET™ switch Modem port to
an SA0142 Adapter. Connect the Adapter's serial connector to the modem's DB-9 port.
8. Use the grounding wire supplied with this package to ground the unit by connecting one end
of the wire to the grounding terminal, and the other end of the wire to a suitable grounded
object.
9. Plug the power cord(s) supplied with this package into the KVM Over the NET™ switch
power socket, and then into an AC power source.
After the KN2116A / KN2132 / KN4116 / KN4132 is cabled up you can turn on the power.
After it is powered up, you can turn on the servers.
6
5
3
1
2
9
8
4
2
1
7
Modem
7
Hardware Installation 3
Mouse DynaSync is only available for Windows and Mac (OS4.0 or higher). Systems connected
to the KN2116A / KN2132 / KN4116 / KN4132 with a KA9170 and KA7170 KVM Adapter,
and whose adapter attribute OS setting is configured for Win or Mac All other configurations
must use manual mouse synchronization. These procedures are to be performed on the
computers attached to the KN2116A / KN2132 / KN4116 / KN4132's ports - not on the
computer you are using to access the KN2116A /KN2132 / KN4116 / KN4132.
Windows Systems:
Note: You must use the generic mouse driver supplied with Windows.
• XP / Server 2003 -- middle position; Enhance pointer precision: off
• 2000 / ME -- Mouse motion: middle position; Acceleration: off
• NT / 98 / 95 -- Mouse speed: slowest
Sun / Linux Systems:
Open a terminal session and issue the following command:
• Sun: xset m 1
• Linux: xset m 0
8
Administrator Setup
Once the KN2116A / KN2132 / KN4116 /
KN4132 has been cabled up, the Super
Administrator needs to set the unit up for user
operation using the local console. When the local
console has been connected up and the KN2116A
/ KN2132 / KN4116 / KN4132 turned on, a login
prompt appears on the console monitor:
Since this is the first time you are logging in, use the default Username: administrator; and the
default Password: password. For security purposes, use the User Management function to
change these to a unique Username and Password
Select Device Management
PN0108
• If you are only using one LAN but connect both ports in case the primary connection fails,
check Redundant NIC; if you are using the secondary LAN port for a second IP address, leave
Redundant NIC unchecked:
• For dynamic IP address assignment, select Obtain an IP address automatically.
• To specify a fixed IP address, select Set IP address manually, and fill in the IP address.
• For automatic DNS Server address assignment, select Obtain DNS Server address automatically.
• To specify the DNS Server address manually, select Use the following DNS Server, and fill in
the addresses for the Primary and Alternate DNS servers.
• If you are using the secondary LAN port for a second IP address, drop down the list under
Redundant NIC and select Network Adapter 2 and set the IP and DNS addresses for it.
To change the default username and password
Modifiy to change the default Super Administrator username and password to something
unique.
To add users, select users in the left panel at the user management page, then click Add the
bottom of the main panel.
Network to set up the switch for network operation.
Select User Management
administrator
9
Operation
After you have successfully logged in, the KN2116A / KN2132 / KN4116 / KN4132 Main Screen appears with
the Port Access page displayed.
The Control Panel
The Control Panel consists of three rows: a row of icons at the top, with two text rows below it.
By default, the upper text row shows the video resolution of the remote display. As the mouse pointer moves
over the icons in the icon bar, however, the information in the upper text row changes to describe the icon's
function. In addition, if a message from another user is entered in the message board, and you have not opened
the message board in your session, the message will appear in the upper row.
The lower row shows the IP address of the device you are accessing at the left of the row. The center of the
row indicates which bus the user is on (the number before the slash), and the total number of users on that bus
(the number behind the slash).
Right clicking in the text row area brings up a menu-style version of the toolbar
The functions that the icons perform are described in the table below:
Control Panel
Zoom in
Macros
On-screen keyboard
Video Options
Mouse pointer type
Video and mouse
Automatic mouse sync
autosync operation
User macros list
Full Screen Mode
Snapshot
Skip to the first port
Skip to the previous
Message Board
port
Click to send a
Skip to the next port
Ctrl+Alt+Del
Toggle color and gray
Skip to the latest port
scale views
Port Operation
The KVM Over the NET™ switch's interface provides a toolbar to help you with port switching operations
from within the captured port. To bring up the toolbar, tap the GUI Hotkey (Scroll Lock or Ctrl) twice. The
toolbar appears at the upper left corner of the screen.
Note:
1. You can adjust the toolbar transparency.
2. The toolbar functions and icons are also incorporated in the Control Panel. If you choose to
enable them in the Control Panel, you can disable the Toolbar . To recall the Port Access
Connections page when there is no Toolbar, simply tap the GUI hotkey twice.
10
Specifications
Function
KN2116A
KN2132
Computer
Direct
16
32
Connections
Max
256 (via Cascade)
512 (via Cascade)
Console
Local
1
1
Connections
Remote
2
2
Port Selection
Pushbutton/ GUI/ Hotkey
Keyboard
1 x 6-pin Mini-DIN , 1 x USB Type A
Console Port
Video
1 x HDB-15
Mouse
1 x 6-pin Mini-DIN, 1 x USB Type A
KVM Port
16 x RJ-45
32 x RJ-45
Connectors
Power
1 x 3-prong AC socket
LAN
2 x RJ-45
PON
1 x RJ-45
Modem
1 x RJ-45
USB
Switches
Reset, Power, Port Selection
LEDs
On Line, Selected, Power, Link 10 / 100 / 1000 Mbps
Emulation
Keyboard/Mouse
PS/2 / USB (PC, Mac, Sun) / Serial
Video
1600 x 1200 @ 60Hz; DDC2B
Scan Interval
1 – 255 Seconds
I/P Rating
100-240VAC; 50-60Hz; 1.0A
110V/33.00W
110V/33.40W
Power Consumption
230V/33.80W
230V/34.20W
Operating Temp.
Environment
Storage Temp.
-20—60℃
Humidity
0—80% RH, Non-condensing
Housing
Physical
Weight
5.46 kg
5.59 kg
Properties
Dimensions ( L x W x H )
43.36 x 41.35 x 4.40 cm(19" 1U)
Auto Scan Mode
Panel Array Mode
Compensation mode
selection
Recall the GUI
Control Panel
Configuration
Exit
Lock indicator
KN4116
KN4132
16
32
256 (via Cascade)
512 (via Cascade)
1
1
4
4
16 x RJ-45
32 x RJ-45
3 x USB
110V/39.60W
110V/45.80W
230V/40.00W
230V/46.30W
0-50℃
Metal
5.52 kg
5.63 kg