QUICKSTART PROGRAMMING OPTIONS ON EACH HARDWIRED TRACKER EXPANSION BOARD GUIDELINES
For COMPLETE programming instructions, please refer to the HARDwired Installation/Owner's manual P/N 2358-065.
BOARD ADDRESS
ON
1
Board addresses MUST be
set for each board used.
0
1
2
3
4
5
6
Data 0
7
Access Control Device
Data 1
26, 30, 31-Bit Wiegand
Com
8
9
12 VDC
10
Tracker Expansion Board Busy
11
12
13
14
15
16
Relay Communication Line (NO)
17
18
Request to Exit
Relay Communication Line (Com)
19
20
Card Reader LED/Beeper Control
LED Display
Basic Programming Sequence on EACH Tracker Expansion Board
Follow these basic steps to perform desired programming, See programming options table for PROGRAM STEPS.
1. Press
arrow buttons or ENT button to ACTIVATE LED display.
2. Press
arrow buttons again to CHOOSE desired PROGRAM STEP.
3. Press ENT button to ENTER desired PROGRAM STEP.
(LED display number will blink after ENT button has been pressed).
4. Press
arrow buttons to choose SELECTION NUMBER for desired function of program step.
5. Press ENT button to program SELECTION NUMBER for desired function of program step.
(Function has now been programmed into board).
6. Press ENT button again to exit programming OR after 10 seconds, board will automatically exit programming.
Note: Repeat these steps for all other desired programming functions.
Each tracker expansion board will have to be INDIVIDUALLY programmed with desired functions.
After all tracker expansion boards have been programmed.....
Manage the Complete Access Control System from Your PC
Refer to the DKS Remote
Account Manager Software
to program and manage the
complete system.
Your PC connected to the access control system.
Either IM Server OR TCP/IP OR RS-232 OR Modem
to Modem Connection. See PC Programmable
Telephone Entry and Access Control Systems
Installation/Owner's manual for more information
about connection options.
RF
OUTPUT
ALARM
AUX
2358-010
SECURE
RF
RF
CODE
CODE
CODE
RELAY
RELAY
RELAY
DATA
STATUS
SENT
GOOD
BAD
NC
NC
NC
Relay jumpers MUST be
NO
NO
NO
set for each relay used.
21
Aux Relay
22
23
Alarm Relay
24
25
Output Relay
26
27
Com
28
Data 1
Tracker Communication Line
29
Data 0
30
(-) 12VDC
Battery
31
(+) 12VDC
Back-Up
32
Ground - Required
33
34
RESET
Board Power
16.5 VAC, 20 VA
Required
ENT
Programming
Buttons
IMPORTANT Display Decimal Point Note
When decimal point is displayed:
Indicates that you are SELECTING
a program step.
When decimal point is NOT displayed:
Indicates that you are IN a program step.
TELEPHONE ENTRY SYSTEM
SP
ABC
DEF
1
2
3
GHI
JKL
MNO
4
5
6
7
PQRS
TUV
8
WXYZ
9
0
OPER
HOLD TO SCAN
A
OPERATING INSTRUCTIONS
1.
Use "A to Z" Buttons to Locate
Name and Code Number on Display.
Names are In Alphabetical Order.
Z
2.
T o Call, Enter Code Number on
Keypad or Press "Call" Button. If
Line is Busy, Press "#" or "Call" to
Hang Up. Try Again.
3.
E nter on Open Display and Tone.
CALL
Programming Options on EACH Tracker Expansion Board
Program
Description
Step
Options
1
Door Strike Timer
00 - 99
2
Free Exit Timer, Strike Time
00 - 99
3
Door Ajar Timer
00 - 99
4
Aux Relay Timer
00 - 99
5
Free Exit Timer, Aux Relay
00 - 99
6
Free Exit, No Strike
7
Not Used
8
Door Contact Switch Logic
9
Auto Relock
10
Beeper / LED Hold Open
11
Hold Open or Hold Egress functions
12
Dual Door Mode
13
Not Used
14
Not Used
15
Aux Relay Functions
Alarm Relay Functions
Door Operation Note:
PROPER Condition:
The access control
system OR request to exit device HAS
activated the OUTPUT RELAY on the
tracker expansion board and the door
contact switch is CLOSED (Door is
OPEN). This indicates that the door has
been PROPERLY OPENED.
16
FORCED Condition:
The access control
system OR request to exit device has
NOT activated the OUTPUT RELAY on
the tracker expansion board and the
door contact switch is CLOSED (Door is
OPEN). This indicates that the door has
been FORCED OPENED.
17
Not Used
18
Not Used
19
Reset to Factory Defaults
20
View RF POT Setting
Adjustable Setting
21
View RF Signal Loss
22
Card Code Forwarding
Copyright 2013 DoorKing, Inc. All rights reserved.
Selection
Function
Number
Sets Strike Time for output relay (term 25 & 26)
00
0.25 second strike time
01 - 99
Strike time in 1-second increments
Set Strike Time for RX (Request to Exit) of output relay (input at term 18)
00
0.25 second Egress Strike time
Egress Strike time in 1-second increments
01 - 99
Timer starts when valid access has been granted.
00
1 second Door Ajar Timer
01 - 99
Timer set in 5-second increments: 01 = 5 seconds, 10 = 50 seconds
Timer setting for Aux Relay activation in 5-second increments
00
1 second Door Ajar Timer
01 - 99
Timer set in 5-second increments: 01 = 5 seconds, 10 = 50 seconds
Set Strike Time for RX (Request to Exit) of Aux relay (ONLY available if Dual Door Mode step 12 is ON)
00
0.25 second Egress Strike time
01 - 99
Egress Strike time in 1-second increments
Set RX (Request to Exit) function. Activate Output Relay or do not Activate Output Relay
0 or 1
0
Do Not Activate Output Relay or Reader Beeper/LED when RX input is received
Activate Output Relay and Reader Beeper/LED for Free Exit Strike Time when RX received
1
Sets type of Door Switch contacts
0
N.O. contact from door switch with Door Closed (Circuit Open - CO)
0 or 1
1
N.C. contact from door switch with Door Closed (Circuit Close - CC)
Turns on Auto Relock function (not available if Dual Door Mode, step 12 is ON)
0 or 1
0
Output Relay is activated for Strike Time
1
Door Contact Switch required. If door returns to closed position during Strike Time
door will "relock" after 1 second, even if strike time has not expired.
Sets how BEEPER or LED will function during Hold Open
0
When Hold Open occurs, Beeper or LED is active only during Strike Timer
0 or 1
1
When Hold Open occurs, Beeper or LED will remain active during Hold Open
Sets how Aux & Alarm Relay responds during Hold Open or Hold Egress situation
0
No Aux Relay functions. Alarm will be in "Reset". If Alarm Relay is set for "integral" mode, Alarm relay will not activate. If
0 or 1
Alarm Relay set for "Bypass" mode, Alarm Relay will activate for Hold Open period or Extended Egress Hold.
1
Aux Relay will function for all settings. If Alarm Relay is set for "integral" mode, Alarm relay will not activate. If Alarm Relay set
for "Bypass" mode, Alarm Relay will activate for Hold Open period or Extended Egress Hold.
Sets Tracker to function as 2 Access Points (2 tracker addresses)
0
Disabled, Tracker functions as single access point
Dual Mode: Tracker functions as set board address and next sequential address
1
Card Read will be sent to controller as set board address, access is granted or denied
0 or 1
Card then sent as set address +1, access granted or denied. Aux Relay becomes 2nd output relay. All other Aux Relay functions
disabled. Door Contact switch becomes RX (Request to Exit) for 2nd address.
Sets function for Aux Relay
0
Aux Relay Disabled
1
No Door Ajar Timer: Requires Door Contact Switch. Aux Relay activates when Door Not Closed.
2
No Door Ajar Timer, Pulse: Requires Door Contact Switch. Aux Relay "pulses" when Door Not Closed.
3
Door Ajar Timer: Requires Door Contact Switch. When door opens, start Door Ajar Timer. When timer expires Aux Relay
activates for Aux Relay timer or until door closes, whichever occurs first.
4
Door Ajar Timer, Pulse: Requires Door Contact Switch. When door opens, start Door Ajar Timer. When timer expires Aux Relay
Pulses for Aux Relay timer or until door closes, whichever occurs first.
5
Door Ajar, Pulse warning the ON: Requires Door Contact Switch. When door opens, Pulse Aux Relay and start Door Ajar Timer.
When timer expires Aux Relay ON for Aux Relay timer or until door closes, whichever occurs first.
0 - 12
6
Door opens for any reason, Start Door Ajar timer and pulse Aux Relay. When Door Ajar timer expires, start Aux Timer and
continue Pulsing Aux Relay.
When Door Closes or both timers expire, turn off Aux Relay
7
Aux Relay as 2nd Alarm Relay. Aux Relay will mirror Alarm Relay functions.
Aux Relay as 2nd Alarm Relay, PULSE. Aux relay will Pulse during any Alarm Relay activation.
8
9
Good Card: Aux Relay will activate for Aux Relay timer for any Access Granted Card
10
Any Card: Aux Relay will activate for Aux Relay Timer when any card has been presented.
11
Bad Card: Aux Relay will activate for Aux Relay timer when a card has been denied
12
Warn before Hold Open or Release of Hold Open: Aux relay will activate for Aux Relay timer when scheduled Hold Open begins
or ends. Output Relay will be delayed until Aux Timer expires. DO NOT set Aux Timer above 60 seconds in this mode.
Sets function for Alarm Relay
0
Aux Relay Disabled
Bypass Mode: Alarm Relay provides "Bypass" to Alarm Door Switch. With proper door input (access or egress) activate Alarm
1
Relay, start Strike timer and Door Ajar timer. When Door Ajar timer expires, deactivate Alarm Relay.
If second Door Contact Switch is provided, generate transaction for Door Ajar and Door Closed following Door Forced condition.
Also generate transaction for Door Forced condition.
Integral Mode, Door Ajar Timer: Door Contact Switch connected to Tracker, Alarm Relay provides connection directly to Alarm
2
System. When door is opened for any reason, start Door Ajar timer. When Door Ajar timer expires and Door is still OPEN,
activate Alarm Relay. Reset when door closes.
Send Door Ajar and Door Close transactions.
0 - 4
Integral Mode, Proper and Forced condition: Door Contact Switch connected to Tracker, Alarm Relay provides connection
directly to Alarm System. With proper door input (access or egress) start Strike timer and Door Ajar timer. When Door Ajar
3
timer expires and Door is still OPEN, activate Alarm Relay. Reset when door closes.
If door is opened without proper condition, activate alarm relay. When door closes deactivate Alarm Relay. Send Door Ajar,
Door Close and Door Forced transactions.
4
Gate Alarm Function: Alarm Relay will activate for 1 second when tracker board receives a "Gate Forced" or "Gate Obstructed"
transaction from the operator control board.
5
Sets all parameters to Factory Default
5
Sets maximum amount of allowable signal strength loss
Displays on LED
Displays current signal loss between Base and Tracker.
Sets Wireless Tracker to act as Repeater
ONLY USE AS DIRECTED BY DOORKING TECH SUPPORT 0=Repeater Mode OFF 1=Repeater Mode ON
0 or 1
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Rev-E 1-13-14
Factory
Default
01 - 1 second
01 - 1 second
12 - 60 secs
12 - 60 secs
01 - 1 second
1 - Activate
0 - N.O.
0 - Disabled
0
0 - No relay
functions
0 - Disabled
0 - Disabled
0 - Disabled
0 - Off
2358-066-F-2-14