ARTRAY ARTCAM-267KY Series Instrukcja obsługi - Strona 8
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Kamera bezpieczeństwa ARTRAY ARTCAM-267KY Series. ARTRAY ARTCAM-267KY Series 18 stron. Artray artcam series ccd cameras
5. Connect the Camera
5-1 How to connect a camera
5-2 Shutter Speed
Shutter speed can be changed on the standard viewer software ART-Viewer.
The shutter speed is set directly on the sensor register, so please refer to the following formulas for the real exposure
time.
Model
445KY2 Series
445SS Series
150PⅢSeries
267KY Series
274KY Series
500PⅡ Series
625KY Series
Range : 2~1083(Exposure Time : 1/22500~1/20.79sec)
Exposure Time=(1084 – Shutter Value)×1600×0.0278 [μsec]
Range : 8~1068(Exposure Time : 1/2234~1/12.5sec)
Exposure Time= (1074 – Shutter Value)×1790×0.0417 [μsec]
Range : 8~1068(Exposure Time : 1/3352~1/19.8sec)
Exposure Time= (1074 – Shutter Value)×1790×0.0278 [μsec]
Range : 2~1252(Exposure Time : 1/18750~1/15sec)
Exposure Time= (1253 – Shutter Value)×1920×0.0278 [μsec]
Range : 1~1013(Exposure Time : 1/8293~1/8.2sec)
Exposure Time=2894× Shutter Value ×0.0417 [μsec]
Range : 2~2079(Exposure Time : 1/9580~1/4.6sec)
Exposure Time= (2080 – Shutter Value)×1924×0.0543 [μsec]
- 8 -
Method
*at 36MHz
*at 24MHz
*at 36MHz
*at 36MHz
*at 24MHz
*at 18.432MHz