ALUZ A1-ZIBI-STN-RGBW Instrukcja instalacji - Strona 8
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Sprzęt oświetleniowy ALUZ A1-ZIBI-STN-RGBW. ALUZ A1-ZIBI-STN-RGBW 12 stron. Surface standard rgbw
1
Measure area where luminaire will be installed. Use a laser line to create
a reference line along installation area, ensuring consistent alignment of
mounting arms. Mark location where each mounting arm will be installed
along reference line.
2
Determine number of mounting arms needed. Use a minimum of 2 mounting
arms per luminaire. Mount arms 6" from center of mounting plate to the end
of luminaire.
Note: Refer to Spacing Diagrams on next page.
3
Mark location where mounting arms will be installed. Screw arm base to
surface using countersink screws of appropriate type and length for surface.
4
Secure luminaire to mounting plates by installing provided #6-20
countersink screws through countersink holes in the bottom of the plate.
Ensure luminaire is secured in place and spacing is accurate according to the
Spacing Diagrams.
5
Loosen set screw until the mounting plate can move freely. Turn the
mounting plate until desired angle is achieved, then mate the locking bump
with locking hole. Tighten set screw until mounting plate is secured in place.
Note: Refer to Angle Increments diagram next page.
Set Screw
Locking Bump
1170 N Red Gum St, Anaheim, CA 92806
aluz.lighting
© ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
A1 Series | Surface
ZIBI Standard RGBW
(A1-ZIBI-STN-RGBW)
Mounting Plate
Locking Hole
866.ALUZ.LTG | 714.535.7900
6
If applicable, connect disconnects between luminaires. Slide shrink tube over
connectors and apply heat. The shrink tube will shrink down, sealing the
connectors. Apply silicone around sealed connectors for a stronger seal.
ASSEMBLED DIMENSIONS
2.52"
4.42"
2.0"
X
Without Louver
SPACING DIAGRAMS
Example: 4' Run
3"
Example: 8' Run
3"
3'6"
Mounting
Arms
4'
Example: 9' Run
3"
3'6"
Mounting
Arms
4'
Bottom Mount Adjustable Arm
(A1-ZIBI-STN-AA-BM-X)
Shrink Tube
2"
Apply Heat
2.60"
5.43"
X
With Louver
3'6"
3"
Mounting
Arms
4'
3"
3"
3'6"
4'
8'
3"
3"
2'6"
3"
3"
3'
9'
Installation Instructions
4 / 29 / 2022 / Rev 2
Page 8 of 12
2.0"
3"
1'6"
3"
2'