Leak Test:

The leak test must be carried out in a well-ventilated area, free from any flames
or other sources of ignition.
Foamy
bubbles
indicate a
leak
Connections to be leak tested
Regulator into cylinder
Hose to regulator
Hose to appliance
Fig.F
Connection
1.
With the cylinder connected to the heater. Open
in assembly
the cylinder valve.
2.
Brush the connections (heater to cylinder) with a
solution of equal parts soap and water (make sure
it's foamy).
3.
A stream of bubbles forming indicates a gas leak.
(See Fig.F)
4.
If bubbles appear, turn the cylinder valve OFF
(clockwise) and disconnect the heater from the
gas cylinder.
5.
Tighten the connection and retry the leak test.
6.
If you are unsure or if you cannot tighten the
connection, place the cylinder outside in a cool,
well-ventilated area and contact ALVA on 086 100
(ALVA) 2582.
7.
A leak between the heater and cylinder can lead
to a high pressure fire, which is very dangerous
and can result in extensive injury or even death.