AKO AKO-59720 Instrukcje - Strona 2

Przeglądaj online lub pobierz pdf Instrukcje dla Przyrządy pomiarowe AKO AKO-59720. AKO AKO-59720 2 stron.

Activating the device
Before activating the device, make sure that there is sufficient coverage at the installation site. Activated devices cannot be
returned.
1. Log into akonet.cloud (you must be registered).
2. Register the new device by clicking on
• Manually enter the serial no. and the activation code that appear on the device's label.
• Click on
and capture the QR code on the device's label (requires the PC or mobile device being used to log into akonet.cloud to
have a camera).
3. Once both steps have been completed, activate the device by holding down the push-button for 9 seconds. The 3 indicator lights will flash.
4. Wait until the process has finished (approximately 3 min.). If the green LED lights up, transmission is OK and the device has been activated
correctly. If the red LED lights up, transmission has failed. The device will make 2 more attempts in the course of 1 hour and will try again
once a day. If the problem persists, check coverage in your area or change the location of the device.
Operation
Push-button (1)
Long press (> 9 sec.): Activates the initial start-up of the device. This should only be done after registering in akonet.cloud. When activated,
the 3 indicators flash and during transmission the blue indicator flashes.
Medium press (> 3 sec.): Triggers data transmission to akonet.cloud. When it wakes up, the 3 indicators flash and during transmission the
blue indicator flashes.
Short press (< 3 sec.): Displays the status of the battery with the green indicator:
ON: Battery OK.
Blinking: Low battery, replace as soon as possible.
Indicator lights
They display the status of the device only after a medium press (transmission triggered), the rest of the time they remain off.
RED (2)
Blinking: An operating error has been detected. After 3 seconds the indicator turns off.
Steady: The transmission could not be carried out; check the coverage. After 3 seconds the indicator turns off.
GREEN (3)
At the end of a transmission, it indicates the current level of coverage:
Steady: Good signal quality
Blinking: Average signal quality
Flashing: Poor signal quality
After 3 seconds the indicator turns off.
BLUE (4)
Blinking: Transmission in progress
Logging and sending data
The device is shipped from the factory in an inactive state, therefore it does not transmit or log any information until it is activated (see "Registering the device").
Once active, the device logs the temperature, humidity, alarm and external probe temperature (depending on model) data at regular intervals. The time between each log is set with the "Data logger
interval frequency" option in the "Parameters / dlG - Data logger" section of akonet.cloud.
The logged data is sent to akonet.cloud when it meets one of the following criteria:
• The time set in the "Transmission Interval to the cloud" option in the "Parameters/ nb - Narrow band" section has elapsed.
• An alarm has been detected that is configured to trigger a transmission .
• A transmission has been triggered by a medium press.
For more information on how akonet.cloud works and how to configure the device, see the online manual of akonet.cloud.
Digital input (black cable)
Connected to a volt-free contact, this input can be used to monitor a digital signal (door activity) or trigger an alarm when the input is activated (active on contact closure/active on contact opening).
This input must be configured in akonet.cloud according to the required application:
• Option A: Each time the input is activated, it generates an event that is stored in the log.
• Option B: The device reads the status of the input as if it were a temperature probe. The reading frequency is set using the "Continuous logging interval" parameter in akonet.cloud.
Technical specifications
Power supply .........................................................................LiSOCI2 battery, 3.6 Vdc, 6.5 Ah
Estimated battery life .......................................................................................up to 2 years*
Measuring range
Temperature probes ........................................................-50ºC to 150ºC
Resolution
Temperature ..................................................................................0.1ºC
Accuracy
from -50ºC to 50 ºC ................................................................. ± 0.5ºC
from -50 ºC to 100ºC .................................................................. ± 1ºC
from 100ºC to 150ºC ................................................................... ± 2ºC
Working ambient temperature ..........................................................................-40ºC to 50ºC
Storage ambient temperature ........................................-40ºC to 60ºC, recommended +30ºC
Permissible humidity range .........................................0% - 100% RH (without condensation)
Protection rating ............................................................................................................ IP68
*Battery life may vary depending on the ambient temperature, the level of coverage and the configuration of the device.
and following one of these two methods:
Bands .............................. NB-IoT (narrow band) LTE Cat NB1 | B2, B3, B4, B8, B12, B13, B20
Band .................... Rx frequency .........................Tx frequency
2 .................. 1930 MHz ~ 1990 MHz.............. 1850 MHz ~ 1910 MHz
3 .................. 1805 MHz ~ 1880 MHz.............. 1710 MHz ~ 1785 MHz
4 .................. 2110 MHz ~ 2155 MHz.............. 1710 MHz ~ 1755 MHz
8 .................... 925 MHz ~ 960 MHz.................. 880 MHz ~ 915 MHz
12 ................... 729 MHz ~ 746 MHz.................. 699 MHz ~ 716 MHz
13 ................... 746 MHz ~ 756 MHz.................. 777 MHz ~ 787 MHz
20 ................... 791 MHz ~ 821 MHz.................. 832 MHz ~ 862 MHz
Maximum transmit power .......................................................................23.5 dBm conducted
Antenna .....................................................................................................................Internal
Dimensions .................................................................107 mm (W) x 85 mm (H) x 39 mm (D)
www.akonet.cloud
3
1
2
4