Re-Lighting
Turn control knob to "OFF" position.
1.
2.
Wait at least 5 minutes, to let gas dissipate, before attempting burner re-light.
Repeat the "Lighting" steps.
3.

LEAKAGE TESTING

Never check for gas leakages with a flame or while smoking.
This appliance needs to be periodically checked for leakages and an immediate check is required if the smell of
gas is detected.
Make a soap solution using 1 part of liquid dish-washing
soap to 3 parts water. The soap solution can be applied
with a soap bottle, brush, or rag to the leakage tested
points shown in the figure beside.
The valve of the LPG cylinder should be in the "OFF"
position at this point of the leakage test. Once the soapy
solution is applied to the gas connections, the valve of the
LPG cylinder needs to be turned to the "ON" position.
Soap bubbles will begin to form in the soapy solution if
any leakage is present.
In the event of gas leakage, the appliance shall not be
used or if alight, the gas supply shall be shut-off and the
appliance shall be investigated and rectified before it is
used again. Tighten any leaking fittings, then turn on gas
supply and recheck.
If necessary, substitute gasket (according to EN 549
Class B2) or material used to guarantee tightness
(according to EN 751-1 Class I).

GAS REQUIREMENTS

Use only the type of gas and the type of LPG cylinder specified by the manufacturer.
Appliance must use an approved gas regulator (approved for a working temperature not lower than 50 ˚C)
according to the EN Standard EN16129 ( gas regulator inlet and outlet connection according to the National
Rules in force) and flexible gas rubber pipe according to applicable EN-standard (with proper inner diameter
according to gas inlet connection and National Rules in force) with a length not over 1.5 m and approved for a
working temperature not lower than 60 ˚C. When substitution will be necessary, you have to purchase suitable
gas regulator, flexible gas rubber pipe and clamps from your local gas dealer; gas regulator should be
substituted not over 10 years.
Flexible gas rubber pipe must be located in the LPG compartment carefully, avoiding any twisting.
Never use a damaged gas regulator.
Never connect this appliance to an unregulated LPG source (gas regulator is mandatory to be used).
When the appliance is not in use, turn the LPG cylinder in "OFF" position.
Always perform a leakage test on gas connections whenever a LPG cylinder is connected. If bubbles form in
the leakage test solution, do not use it. Never use a flame to test for leakages. It is strictly forbidden and
dangerous!
Leakage Test Point ① ② ③ ④
8 of 11