AKOS Meridian XL Instrukcja instalacji - Strona 18
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Kominek wewnętrzny AKOS Meridian XL. AKOS Meridian XL 20 stron. Insert fireplace
Checking the flame picture
Allow the appliance to burn for at least 20 minutes at full burb capacity and then check the flame
picture for:
1. Distribution of the flames
2. Color of the flames
If either one or both points are unacceptable, then check:
•
The positioning of the imitation logs and/or the quantity of pebbles or chips on the burner.
•
The connections of the Flue materials for leakage (in case of blue flames)
•
Whether the correct flue restrictor has been mounted
•
The outlet.
•
Wall terminal is installed correctly
•
Roof terminal is fitted and sited correctly
•
The flue system is correctly calculated
Checking the flue pipe system
− Let the fireplace burn on full output.
− Check the flame image to see if there is an even distribution of flames. In case of the uneven
flame distribution adjust the position of decorative material (ceramic logs, pebbles, chips) until
you get a desired distribution of flames.
− After 20 minute check if the flame color is a nice and clear yellow. In case of blue flames turn off
the fire and check the following things:
-
That there is no leakage in the pipe connections.
-
Mounting of the outlet. In case of it penetrating the wall, the proper side up.
In case of a roof terminal, see if it's located in a proper position (consult with chapter
-
3)
-
Whether the maximum length of the flue pipe has not been exceeded.
-
Correct settings of the fireplace deflector.
10 Conversion to a different type of gas (e.g. propane)
− This can only be done by installing the proper burner unit. For this purpose get in touch with your
supplier.
− Always mention the type and serial number of the appliance when ordering.
− For the process of conversion follow the following steps:
-
Remove glass
-
Remove burner
-
Change injectors to the ones appropriate for the specific gas.
-
For LPG gas open the primary air limiter and for NG gas, close the primary air limiter,
as shown in the illustration below
-
Place the new burner appropriate for the specific gas.
-
Go through stages of chapter 9.39Final Inspection
-
Close the glass.
AKOS Sp. z o o.
ul. Bruszewska 22, 03-046 Warszawa
NIP: 5361925006; REGON 365653140
Tel: +48881697975; email: [email protected]
18 <
<
<
<