INTRODUCTION
Your Audio/Video components are constantly
High-Current Outlet Bank:
being bombarded by electromagnetic interfer-
The unique power requirements of current
ence (EMI) and radio frequency interference
hungry components such as amplifiers and
(RFI) through their power cords. This contam-
powered subwoofers are also addressed.
inated power can affect A/V equipment and will
These components can rapidly draw large
degrade the overall performance of your entire
amounts of current to replenish their power
system. Common symptoms of contaminated
supply capacitors after thunderous bass notes.
power include pops, hisses, hums, visual arti-
Line conditioners that utilize coils (inductors)
facts, etc. Most power filtering devices will
in series with the AC power line can "choke"
remove some of this interference but don't
off this large inrush current, thereby reducing
provide a real solution to the problem.
the amplifiers' ability to operate at peak
performance levels, resulting in a flat, dead
The PD11VBC Sophisticated Filtration
sound. The PD11VBC high-current outlets
System is a Real Solution!
are fed by noise filtration circuitry that does
not utilize coils and provides full, unimpeded
Outlet Banks 1 & 2:
power for your amplifiers and powered sub-
The primary filtration system features two
woofers.
banks of independently filtered outlets (4 per
bank) for A/V equipment. These outlet banks
Other Features Enhance the
utilize "Balanced Double L" filter circuits
Functionality:
which are far superior to any other design in
Although the PD11VBC functionality revolves
filtering out all forms of electromagnetic and
around noise filtration and power protection,
radio frequency interference in both common
many other exciting features enhance the overall
and normal modes. Cross-contamination
entertainment experience, including:
between your components is also eliminated
•
A backlit analog voltmeter indicates the AC
with this design. Bank 1 is Always-On,
line voltage coming into your system.
providing continuous power for those compo-
nents that have programmable memory
•
A combination ON/OFF/Dimmer switch
settings. Bank 2 can be set to either
controls the meter lighting.
Always-On or switched with a shutdown delay.
•
An always-on, convenience outlet on the
front panel for temporary AC connections.
•
Sequential start-up and shut-down of your
system using an A/V receiver (or other
component) and the 12VDC trigger input.
2
1532 Enterprise Pkwy, Twinsburg OH 44087 • (800) 321-6699 • (330) 425-3388 • www.etasys.com
As you read through the rest of this manual,
you'll discover many more unique features.
As audiophiles, we care about the quality of
your listening and/or viewing experience.
Our goal is to:
• Provide clean pure power
• Protect your investment
• Enhance the pleasure you get from you're
A/V system
Thank you for choosing ETA for your power
quality needs. Please finish reading the
instructions, install your PD11VBC and enjoy
the full potential of your entertainment sys-
tem.
TECHNICAL SPECIFICATIONS
GENERAL
Dimensions..........................17" W x 12" D x 3.5" H, (4.1" Including Feet)
Weight.............................................................................................16 lbs.
AC CIRCUIT
NOISE FILTRATION:
Filtered Outlet Banks........................................................55 dB (100 KHz - 1 MHz)
High-Current Outlets.......................................................50 dB (100 KHz - 1 MHz)
SURGE PROTECTION:
UL 1449 Surge Suppression Rating................................................................330V
Protection Modes....................................................................... L - N, L - G, N - G
Initial Clamping Level..........................................................200V Peak, 141V Rms
Response Time...............................................................................................<1ns
Joule Rating........................................................................................1790 Joules
Peak Impulse Current...............................................................................65,000A
Catastrophic Surge Circuit ..............................................................................YES
AC:
Line Voltage...............................................................................................120VAC
Max Current Rating......................................................................15A (1800 Watts)
Thermal Fuse...................................................................................................YES
Over/Under Voltage Protection.........................................................................YES
Over-voltage shutoff threshold..................................137±4 VAC, 10 Milliseconds
Under-voltage shutoff threshold...............................95±4 VAC, 500 Milliseconds
Design and specifications subject to change without notice due to product improvement.
CONTACTING ETA
For product and warranty information, dealer information, and other general information contact
Customer Relations at:
• Email: [email protected]
• www.etasys.com
• Fax 330-425-9700
• 800-321-6699 or 330-425-3388, 7:30 a.m.- 5:30 p.m. EST
1532 Enterprise Pkwy, Twinsburg OH 44087 • (800) 321-6699 • (330) 425-3388 • www.etasys.com
DC TRIGGER
Connection........................................................................3.5mm mono mini-plug
Voltage and Polarity............................................3-18VDC nominal, bi-directional
Current Requirement.....................................................................................25mA
SATELLITE CIRCUIT
Clamping Level................................................................................................27V
Attenuation...............................................................<1 dB from 950MHz - 2.2GHz
Shielded...........................................................................................................YES
Connections......................................................................Gold plated, Female "F"
ANT/CATV CIRCUIT
Clamping Level...............................................................................................0.7V
Attenuation..................................................................<1 dB from 5MHz -950MHz
Shielded...........................................................................................................YES
Connections......................................................................Gold plated, Female "F"
TELEPHONE CIRCUIT
Clamping Level..............................................................................................260V
Capacitance......................................................................................30pf (approx.)
Suppression Modes...........................................................Metallic & Longitudinal
Wires Protected....................................................................2 wire/ 1 pr. (pins 4,5)
Fuseless/Auto-Resetting..................................................................................YES
Connections............................................................................................RJ-11/45
11